MétaCan
Menu
Back to cohort
Record W4301354523

Remote Monitoring of Implantable Cardioverter-Defibrillators, Cardiac Resynchronization Therapy and Permanent Pacemakers: A Health Technology Assessment.

2018· article· en· W4301354523 on OpenAlexaboutno aff

Bibliographic record

VenuePubMed · 2018
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCardiac resynchronization therapyImplantable cardioverter-defibrillatorRandomized controlled trialHealth careMedical emergencyGrading (engineering)Emergency medicineIntensive care medicinePhysical therapyHeart failureInternal medicine
DOInot available

Abstract

fetched live from OpenAlex

BACKGROUND: Under usual care, people with an implantable cardioverter-defibrillator (ICD), cardiac resynchronization therapy with or without a defibrillator (CRT-D and CRT-P, respectively), or a permanent pacemaker have follow-up in-person clinic visits. Remote monitoring of these devices allows the transfer of the information stored in the device so that it can be accessed by the clinic personnel via a secured website. METHODS: We completed a health technology assessment, which included an evaluation of clinical benefits and harms, value for money, and patient preferences for remote monitoring of ICDs, CRTs, and permanent pacemakers plus clinic visits compared with clinic visits alone. This is an update of a 2012 health technology assessment. In addition to the eligible randomized controlled trials (RCTs) from the 2012 publication, we included RCTs identified through a systematic literature search on June 1, 2017. We assessed the risk of bias of each study using the Cochrane risk of bias tool and the quality of the body of evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We conducted an economic evaluation to determine the cost-effectiveness of remote monitoring blended with in-clinic follow-up compared to in-clinic follow-up alone in patients with an ICD, a CRT-D, or a pacemaker. We determined the budget impact of blended remote monitoring in patients implanted with ICD, CRT-D, CRT-P, or pacemaker devices from the perspective of the Ontario Ministry of Health and Long-Term Care. To understand patient experiences with remote monitoring, we interviewed 16 patients and family members. RESULTS: Based on 15 RCTs in patients with implanted ICDs or CRT-Ds, remote monitoring plus clinic visits resulted in fewer patients with inappropriate ICD shocks within 12 to 37 months of follow-up (moderate quality evidence; absolute risk difference -0.04 [95% confidence interval -0.07 to -0.01]), fewer total clinic visits (moderate quality evidence), and a shorter time to detection and treatment of events (moderate quality evidence) compared with clinic visits alone. There was a similar risk of major adverse events (moderate quality evidence).Based on 6 RCTs in patients with pacemakers, remote monitoring plus clinic visits reduced the arrhythmia burden (high quality evidence), the time to detection and treatment of arrhythmias (high quality evidence), and the number of clinic visits (moderate quality evidence]) compared with clinic visits alone. Here again, there was a similar risk of major adverse events (high quality evidence).Results from the economic evaluation showed that among ICD and CRT-D recipients, blended remote monitoring (remote monitoring plus in-clinic follow ups) was more costly (incremental value of $4,354 per person) and more effective, providing higher quality-adjusted life years (incremental value of 0.19), compared to in-clinic follow-up alone. Among pacemaker recipients, blended remote monitoring was less costly (with an incremental saving of $2,370 per person) and more effective (with an incremental value of 0.12 quality-adjusted life years) than with in-clinic follow-up alone. We estimated that publicly funding remote monitoring could result in cost savings of $14 million over the first five years.Participants using remote monitoring reported that these devices provide important medical and safety benefits in managing their heart condition. Remote cardiac monitoring provides patients and their family members with an increased freedom. Their belief that the device will help with earlier detection of technical or clinical problems reduces the amount of stress and distraction their condition causes in their lives. CONCLUSIONS: Remote monitoring of ICDs, CRT-Ds, and pacemakers plus clinic visits resulted in improved outcomes without increasing the risk of major adverse events compared with clinic visits alone. Remote monitoring is a cost-effective option for patients implanted with cardiac electronic devices. Patients reported positive experiences using remote monitoring, and perceived that the device provided important medical and safety benefits.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.328
Threshold uncertainty score0.504

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.312
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations37
Published2018
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicCardiac pacing and defibrillation studiesFrench-language works237,207