MétaCan
Menu
Back to cohort
Record W4302027700 · doi:10.1177/17585732221128964

Stabilizing effect of an elbow orthosis with an adjustable hinge axis after lateral collateral ligament injury: A biomechanical study

2022· article· en· W4302027700 on OpenAlexafffund
Armin Badre, David Axford, Sara Kotzer, James A. Johnson, Graham JW King

Bibliographic record

VenueShoulder & Elbow · 2022
Typearticle
Languageen
FieldMedicine
TopicElbow and Forearm Trauma Treatment
Canadian institutionsSt Joseph's Health CareWestern UniversitySturgeon Community HospitalUniversity of Alberta
FundersPhysicians' Services Incorporated Foundation
KeywordsElbowValgusMedicineBraceCadaveric spasmLigamentMedial collateral ligamentOrthodonticsForearmHingeAnatomyStructural engineeringEngineering

Abstract

fetched live from OpenAlex

Background: Current commercial elbow braces have a straight hinge that does not account for the native carrying angle of the elbow. The objective of this study was to determine the effectiveness of a custom-designed hinged elbow orthosis (HEO) with variable valgus angulations in stabilizing a lateral collateral ligament (LCL) deficient elbow. Methods: Eight cadaveric upper extremities were mounted in an elbow motion simulator in the abducted varus gravity-loaded position. The specimens were examined before and after simulated LCL injury and then with the addition of the custom-designed HEO with 0°, 10°, and 20° of valgus angulation. Kinematic data were recorded using an electromagnetic tracking system. Results: < 0.05). There were no significant differences in varus-valgus angulation or ulnohumeral rotation between any of the brace angles and the LCL injured state with the forearm pronated and supinated. Discussion: The custom-designed HEO did not provide any additional stability to the LCL injured elbow. The varus arm position should be avoided during the rehabilitation of an LCL injured elbow even when an HEO is used.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.301
Teacher spread0.286 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueShoulder & ElbowSame topicElbow and Forearm Trauma TreatmentFrench-language works237,207