FLASH Radiotherapy for the Treatment of Symptomatic Bone Metastases (FAST-01): Protocol for the First Prospective Feasibility Study
Bibliographic record
Abstract
BACKGROUND: In preclinical studies, FLASH therapy, in which radiation delivered at ultrahigh dose rates of ≥40 Gy per second, has been shown to cause less injury to normal tissues than radiotherapy delivered at conventional dose rates. This paper describes the protocol for the first-in-human clinical investigation of proton FLASH therapy. OBJECTIVE: FAST-01 is a prospective, single-center trial designed to assess the workflow feasibility, toxicity, and efficacy of FLASH therapy for the treatment of painful bone metastases in the extremities. METHODS: Following informed consent, 10 subjects aged ≥18 years with up to 3 painful bone metastases in the extremities (excluding the feet, hands, and wrists) will be enrolled. A treatment field selected from a predefined library of plans with fixed field sizes (from 7.5 cm × 7.5 cm up to 7.5 cm × 20 cm) will be used for treatment. Subjects will receive 8 Gy of radiation in a single fraction-a well-established palliative regimen evaluated in prior investigations using conventional dose rate photon radiotherapy. A FLASH-enabled Varian ProBeam proton therapy unit will be used to deliver treatment to the target volume at a dose rate of ≥40 Gy per second, using the plateau (transmission) portion of the proton beam. After treatment, subjects will be assessed for pain response as well as any adverse effects of FLASH radiation. The primary end points include assessing the workflow feasibility and toxicity of FLASH treatment. The secondary end point is pain response at the treated site(s), as measured by patient-reported pain scores, the use of pain medication, and any flare in bone pain after treatment. The results will be compared to those reported historically for conventional dose rate photon radiotherapy, using the same radiation dose and fractionation. RESULTS: FAST-01 opened to enrollment on November 3, 2020. Initial results are expected to be published in 2022. CONCLUSIONS: The results of this investigation will contribute to further developing and optimizing the FLASH-enabled ProBeam proton therapy system workflow. The pain response and toxicity data acquired in our study will provide a greater understanding of FLASH treatment effects on tumor responses and normal tissue toxicities, and they will inform future FLASH trial designs. TRIAL REGISTRATION: : ClinicalTrials.gov NCT04592887; http://clinicaltrials.gov/ct2/show/NCT04592887. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/41812.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.023 | 0.013 |
| Meta-epidemiology (narrow) | 0.004 | 0.002 |
| Meta-epidemiology (broad) | 0.004 | 0.002 |
| Bibliometrics | 0.001 | 0.002 |
| Science and technology studies | 0.003 | 0.003 |
| Scholarly communication | 0.002 | 0.002 |
| Open science | 0.003 | 0.002 |
| Research integrity | 0.005 | 0.006 |
| Insufficient payload (model declined to judge) | 0.050 | 0.016 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".