MétaCan
Menu
Back to cohort
Record W4304184354 · doi:10.1111/jce.15701

Combined pulsed field ablation with ultra‐low temperature cryoablation: A preclinical experience

2022· article· en· W4304184354 on OpenAlexaff
Atul Verma, Gregory K. Feld, James L. Cox, Thomas A. Dewland, А. В. Бабкин, Tom De Potter, Narayan R. Raju, Michel Haı̈ssaguerre

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2022
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsCryoablationMedicineAblationCatheter ablationMicrobubblesBiomedical engineeringLesionRadiologyCardiac AblationNuclear medicineUltrasoundPathologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Combining pulsed field ablation (PFA) with ultra-low temperature cryoablation (ULTC) represents a novel energy source which may create more transmural cardiac lesions. We sought to assess the feasibility of lesions created by combined cryoablation and pulsed field ablation (PFCA) versus PFA alone. METHODS: Ablations were performed using a custom PFA generator, ULTC console, and an ablation catheter with insertable stylets. PFA was delivered in a biphasic, bipolar train. PFCA precooled the tissue for 30 s followed by a concurrent PFA train. Benchtop testing using Schlieren imaging and microbubble volume assessment were used to compare PFA and PFCA. PFA and PFCA lesions using pre-optimized and optimized ablation protocols were studied in 6 swine. Pre and post-ECGs were recorded for each ablation and a gross necropsy was performed at 14 days. RESULTS: Consistent with benchtop comparisons of heat and microbubble generation, PFA deliveries in the animals were accompanied by muscle contractions and significant microbubbles (Grade 2-3) visible on intracardiac echo while neither occurred during PFCA at higher voltage levels. Both PFA and PFCA acutely eliminated or highly attenuated (>80%) local atrial electrograms. Histology of PFA and PFCA lesions indicated depth up to 6-7 mm and nearly all lesions were transmural. Optimized PFCA produced wider cavotricuspid isthmus lesions with evidence of tissue selectivity. CONCLUSION: A novel technology combining PFA and ULTC into one energy source demonstrated in-vivo feasibility for PFCA ablation. PFCA had a more favorable thermal profile and did not produce muscle contraction or microbubbles while extending lesion depth beyond cryoablation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.252
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations27
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207