MétaCan
Menu
Back to cohort
Record W4305042191 · doi:10.1371/journal.pone.0268456

Coronary bioresorbable stents: Non-invasive quantitative evaluation of intra- and juxta-stent plaque composition—A computed tomography longitudinal study

2022· article· en· W4305042191 on OpenAlexafffund
Evguenia Zdanovich, Samer Mansour, Louis‐Mathieu Stevens, Charbel Naim, Daniel Juneau, Alexandre Semionov, Carl Chartrand‐Lefebvre

Bibliographic record

VenuePLoS ONE · 2022
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsMcGill University Health CentreCentre Hospitalier de l’Université de Montréal
FundersRéseau en Bio-Imagerie du QuebecAbbott Laboratories
KeywordsMedicineStentRadiodensityNuclear medicineRadiologyIntravascular ultrasoundJuxtaRadiographySurgery

Abstract

fetched live from OpenAlex

PURPOSE: Coronary bioresorbable stents (BRS) do not produce blooming artifacts on computed tomography (CT), in contrast to metallic stents, as they are made of a bioresorbable polymer and are radiolucent. They allow to evaluate the coronary plaque beneath. The low-attenuation plaque (LAP) suggests plaque vulnerability and is CT assessable. The aim of our study was to show the possibility of a non-invasive CT evaluation of the volume and the LAP composition of the intra- and juxta-stent plaque. METHODOLOGY: In our prospective longitudinal study, we recruited 27 consecutive patients (35 BRS stents total; mean age 60 +/- 9 years) with bioresorbable stents for a 256-slice ECG-synchronized CT evaluation at 1- and 12-months post stent implantation. Total plaque volume (mm3), absolute and relative (%) LAP volume per block in the pre- intra- and post-stent zones were analyzed; comparison 1- and 12-months post-implantation of BRS. Changes in the previously mentioned variables were assessed by the mixed effects models with and without spline, which also accounted for the correlation between repeated measurements. RESULTS: Our block or spline model analysis has shown no significant difference in plaque or absolute LAP volumes in pre- intra- and post-stent zones between 1 and 12 months. Interestingly, % LAP volume increases near-significantly in the distal block of the intrastent at 12-mo follow-up (from 23.38 ± 1.80% to 26.90 ± 2.22% (increase of 15%), p = 0.052). CONCLUSION: Our study demonstrates the feasibility of the repeated non-invasive quantitative analysis of the intrastent coronary plaque and of the in-stent lumen by CT scan.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.091
GPT teacher head0.305
Teacher spread0.214 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2022
Admission routes2
Has abstractyes

Explore more

Same venuePLoS ONESame topicCardiac Imaging and DiagnosticsFrench-language works237,207