MétaCan
Menu
Back to cohort
Record W4307711451 · doi:10.12968/bjon.2022.31.19.s16

Central venous access device locking practices in the adult critical care setting: a single-centre, observational study establishing duration of locking per catheter lumen

2022· article· en· W4307711451 on OpenAlexaff
Marlena Ornowska, Jessica Wittmann, Steven Reynolds

Bibliographic record

VenueBritish Journal of Nursing · 2022
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsRoyal Columbian HospitalSimon Fraser University
Fundersnot available
KeywordsCentral lineObservational studyMedicineCentral venous catheterCatheterIntensive care medicinePsychological interventionRandomized controlled trialPopulationPeripherally inserted central catheterEmergency medicineSurgeryInternal medicineNursing

Abstract

fetched live from OpenAlex

PURPOSE: Central line complications remain a problem in critical care patient populations. Various interventions to prevent or treat complications, such as central line-associated bloodstream infection and occlusion, have been the focus of recent research. Although alternative catheter locking solutions have been shown to be effective in other patient populations, their applicability to the critical care setting remains unclear. Due to the high acuity of critical care patients, it is uncertain whether their central lines remain locked for a duration long enough for alternative locking solutions to provide any effect. METHODS: This single-centre, prospective, observational study aimed to gather information about the length of time central line lumens remain in a locked state in the average critical care patient. Baseline rates of various central line complications were also tracked. RESULTS: Results of this study indicate that the majority of central lines will have at least one lumen locked for an average of 36.6% of their time in situ. CONCLUSIONS: It is anticipated that this length of time provides enough exposure for alternative locking solutions to potentially make a difference in central line complications in this patient population. Results of this study can be used for planning future multi-centre, randomized controlled trials investigating the efficacy of novel central line locking solutions to prevent central line complications in critically ill patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.205
GPT teacher head0.449
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of NursingSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207