MétaCan
Menu
Back to cohort
Record W4308045217 · doi:10.1007/s40123-022-00604-w

Effects of Serial Sessions of Activa Mask for the Treatment of Meibomian Gland Dysfunction

2022· article· en· W4308045217 on OpenAlexaboutno aff
Luca Vigo, Marco Pellegrini, Sergio D’Angelo, Francesco Carones, Vincenzo Scorcia, Giuseppe Giannaccare

Bibliographic record

VenueOphthalmology and Therapy · 2022
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineMeibomian glandAnatomyOphthalmologyEyelid

Abstract

fetched live from OpenAlex

INTRODUCTION: To analyze outcomes on objective ocular surface parameters and subjective symptoms of serial weekly sessions using the Activa mask in patients with meibomian gland dysfunction (MGD). METHODS: This is a prospective study including patients with symptomatic MGD who were treated with four weekly sessions using the Activa mask (SBM Sistemi, Turin, Italy). Noninvasive ocular surface examination was carried out before (T0) and 2 weeks after the last mask session (T1) using Idra (SBM Sistemi, Turin, Italy) for the measurement of: (1) noninvasive break-up time (NIBUT); (2) lipid layer thickness (LLT); (3) tear meniscus height (TMH); (4) meibomian gland loss (MGL) of upper and lower eyelids. The I-Pen tear osmolarity system (I-Med Pharma Inc, Dollard-des Ormeaux, Quebec, Canada) was used to measure tear osmolarity values. Ocular discomfort symptoms were ascertained by means of the ocular surface disease index (OSDI) questionnaire. RESULTS: All 25 patients (11 males, 14 females; mean age 57.1 ± 11.9 years) regularly completed the cycle of four mask sessions. No patients used prohibited medications, and no device-related adverse events were noted. At T1, mean values of NIBUT and LLT increased significantly compared to T0 (respectively from 6.0 ± 1.4 to 6.6 ± 1.2 s, P = 0.043, and from 53.2 ± 17.4 to 65.3 ± 16.3 nm, P < 0.001), while mean values of MGL and tear osmolarity decreased significantly (respectively from 17.1 ± 9.3 to 15.1 ± 8.0%, P = 0.014, and from 307.3 ± 12.2 to 301.5 ± 6.8 mOsm/l, P = 0.005). In parallel, OSDI score reduced significantly from 62.4 ± 11.7 at T0 to 34.5 ± 11.2 at T1 (P < 0.001). CONCLUSION: Weekly serial sessions using the Activa mask significantly improved objective parameters of the ocular surface as well as subjective ocular discomfort symptoms in patients with recalcitrant MGD. As a further benefit from the treatment, patients were able to avoid the use of concomitant medications, apart from tear substitutes, throughout the study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.288
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueOphthalmology and TherapySame topicOcular Surface and Contact LensFrench-language works237,207