MétaCan
Menu
Back to cohort
Record W4308317790 · doi:10.1186/s43065-022-00061-6

Seismic collapse risk of RC-timber hybrid building with different energy dissipation connections considering NBCC 2020 hazard

2022· article· en· W4308317790 on OpenAlex
Ikenna Odikamnoro, Prakash S. Badal, Henry V. Burton, Solomon Tesfamariam

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueJournal of Infrastructure Preservation and Resilience · 2022
Typearticle
Languageen
FieldEngineering
TopicSeismic Performance and Analysis
Canadian institutionsUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsDissipationHazardStructural engineeringEngineeringForensic engineeringPhysicsBiologyEcology

Abstract

fetched live from OpenAlex

The 2020 National Building Code of Canada (NBCC) seismic hazard model (SHM) marks a comprehensive update over its predecessor (NBCC 2015). For different regions in Canada, this will have an impact on the design of new buildings and performance assessment of existing ones. In the present study, a recently developed hybrid building system with reinforced concrete (RC) moment-resisting frames and cross-laminated timber (CLT) infills is assessed for its seismic performance against the latest SHM. The six-story RC-CLT hybrid system, designed using the direct displacement-based method, is located in Vancouver, Canada. Along with very high seismicity, southwestern British Columbia is characterized by complex seismotectonics, consisting of subduction, shallow crustal, and in-slab faulting mechanisms. A hazard-consistent set of 40 ground motion pairs is selected from the PEER and KiK-net databases, and used to estimate the building's seismic performance. The effects of using steel slit dampers (associated with large hysteresis loops) and flag-shaped energy dissipators (associated with the recentering capability) are investigated. The results indicate that the hybrid system has good seismic performance with a probability of collapse of 2-3% at the 2475-year return period shaking intensity. The hybrid building with steel slit dampers exhibits a collapse margin ratio of 2.8, which increases to 3.5-3.6 when flag-shaped dissipators are used. The flag-shaped dissipators are found to significantly reduce the residual drift of the hybrid building. Additionally, the seismic performance of the hybrid building equipped with flag-shaped dissipators is found to improve marginally when the recentering ratio is increased.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.063
Threshold uncertainty score0.351

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.199
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it