MétaCan
Menu
Back to cohort
Record W4308685709 · doi:10.1002/acm2.13815

Volume staging for arteriovenous malformation SRS treatment using VMAT

2022· article· en· W4308685709 on OpenAlexaff
Claudia Mendez, Ermias Gete

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2022
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsAbbotsford Veterinary ClinicUniversity of British Columbia
Fundersnot available
KeywordsNuclear medicineRadiosurgeryTruebeamMedicineArteriovenous malformationLinear particle acceleratorRadiation therapyRadiologyPhysicsBeam (structure)

Abstract

fetched live from OpenAlex

Abstract Volume staging involves dividing the target volume into smaller parts and treating each part separately. In this study, the feasibility of volume‐staged stereotactic radiosurgery (VS‐SRS) on a linear accelerator using volumetric modulated arc therapy (VMAT) and a frameless patient positioning system is investigated. Ten patients, previously treated with hypofractionated stereotactic radiotherapy with arteriovenous malformation (AVM) sized from 1.6 to 4.0 cm in diameter, were selected. VS‐SRS plans were created with the VMAT technique on the Varian Eclipse treatment planning system (TPS) using the TrueBeam STx linear accelerator. For each patient, an AVM‐VMAT set was planned with the AVM as the target and a PTV‐VMAT set using the (PTV = AVM+1 mm) as the target. All targets were divided into two sub‐volumes. The TPS data from the AVM‐VMAT plans was compared to Gamma Knife (GK) VS‐SRS plan data available in the literature. The AVM‐VMAT and PTV‐VMAT plans were compared to investigate the effect of a 1 mm PTV margin on normal brain (NB) dose. End‐to‐end testing was performed using a GaFchromic EBT3 film and point‐dose measurements. Dosimetric effects of multiple setups were investigated through film‐to‐film comparisons. Median target dose coverage, NB V 12Gy , and conformity index for the AVM‐VMAT plans were 97.5%, 17 cm 3 , and 0.8, respectively. PTV‐VMAT plans attained comparable target dose coverage, but the average NB V 12Gy increased by 48.9% when compared to the AVM‐VMAT plans. Agreement of point‐dose measurements with TPS calculations was −0.6% when averaged over all patients. Gamma analysis passing rates were above 90% for all film‐to‐film comparisons (2%/1 mm criteria), and for the film to TPS comparison (5%/1 mm). This work suggests that VMAT is capable of producing VS‐SRS plans with similar dose falloff characteristics as GK plans. NB dose depends on PTV margin size, and two‐stage treatment setups do not appear to contribute additional uncertainty to treatment delivery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.972
Threshold uncertainty score0.516

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.374
Teacher spread0.335 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207