A Novel Mask with Selective Ports for Inflow and Outflow Reduces CO2 Rebreathing during Non-Invasive Ventilation: A Physiological Study in Healthy Volunteers

2022· article· en· W4308768696 on OpenAlexaff
Emanuele Rezoagli, Davide Signori, Alice Grassi, F Rabboni, Alberto Lucchini, Giacomo Bellani, Giuseppe Foti

Bibliographic record

VenueRespiration · 2022
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsMedicineVentilation (architecture)Nasal cannulaTidal volumeAnesthesiaCannulaPositive end-expiratory pressureMechanical ventilationRespiratory systemSurgeryInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: CO2 rebreathing is one of the risks associated with noninvasive ventilation (NIV), possibly contributing to failure. In a bench study, we showed that a novel mask design, with separate limbs for inflow and outflow gases, significantly reduced CO2 rebreathing in different ventilation settings. OBJECTIVES: The study aimed to test whether a new mask design could 1) reduce CO2 rebreathing in healthy volunteers during NIV (phase 1) and 2) reduce minute ventilation (phase 2). MATERIALS AND METHODS: Healthy volunteers were randomly assigned to NIV using two masks in a crossover design: a traditional single-limb mask for inflow and outflow gases and a mask with two separated limbs. In phase 1, six ventilation settings were tested for each mask: CPAP (PEEP 5 cmH2O) and pressure support ventilation (PSV, PS Level 5 cmH2O) using a mechanical ventilator with a bias flow of 8 or 20 L/min; free-flow CPAP (PEEP 5 cmH2O) with 60 or 90 L/min of gas flow. A nasal cannula was inserted in one nostril of the volunteers and connected to a CO2 gas analyzer to measure CO2 during the respiratory cycle. In phase 2, volunteers underwent a prolonged time of ventilation in CPAP 90 L/min and PSV with 20 L/min of bias flow. During free-flow CPAP, electrical impedance tomography was used to record the change in impedance during tidal breathing and then estimate tidal volume. RESULTS: Ten healthy adults were enrolled in phase 1, and 8 volunteers in phase 2. CO2 during inspiration was significantly lower in each setting with the two-limb versus the one-limb mask (p < 0.001). The maximum CO2 reduction was observed in the continuous-flow CPAP settings. EtCO2 was lower with the two-limb mask compared to the one-limb mask (p < 0.001). However, no difference in minute ventilation was observed between the two masks. CONCLUSION: The new mask design with two ports for inhaled and exhaled gases reduced the amount of CO2 rebreathing in all tested ventilation settings. The CO2 rebreathing reduction did not decrease minute ventilation in healthy volunteers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.742
Threshold uncertainty score0.505

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.292
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueRespirationSame topicRespiratory Support and MechanismsFrench-language works237,207