MétaCan
Menu
Back to cohort
Record W4309366885 · doi:10.1002/mp.16110

A novel tissue mechanics‐based method for improved motion tracking in quasi‐static ultrasound elastography

2022· article· en· W4309366885 on OpenAlexafffund
Niusha Kheirkhah, Sergio Dempsey, Ali Sadeghi‐Naini, Abbas Samani

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsHealth Sciences CentreYork UniversitySunnybrook Health Science CentreWestern University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsElastographyImaging phantomStiffnessUltrasoundDisplacement (psychology)Ultrasound elastographyContrast-to-noise ratioBiomedical engineeringComputer scienceMaterials scienceAcousticsImage qualityArtificial intelligencePhysicsOpticsMedicine

Abstract

fetched live from OpenAlex

PURPOSE: Most cancers are associated with biological and structural changes that lead to tissue stiffening. Therefore, imaging tissue stiffness using quasi-static ultrasound elastography (USE) can potentially be effective in cancer diagnosis. USE techniques developed for stiffness image reconstruction use noisy displacement data to obtain the stiffness images. In this study, we propose a technique to substantially improve the accuracy of the displacement data computed through ultrasound tissue motion tracking techniques, especially in the lateral direction. METHODS: The proposed technique uses mathematical constraints derived from fundamental tissue mechanics principles to regularize displacement and strain fields obtained using Global Ultrasound Elastography (GLUE) and Second-Order Ultrasound Elastography (SOUL) methods. The principles include a novel technique to enforce (1) tissue incompressibility using 3D Boussinesq model and (2) deformation compatibility using the compatibility differential equation. The technique was validated thoroughly using metrics pertaining to Signal-to-Noise-Ratio (SNR), Contrast-to-Noise-Ratio (CNR) and Normalized Cross Correlation (NCC) for four tissue-mimicking phantom models and two clinical breast ultrasound elastography cases. RESULTS: The results show substantial improvement in the displacement and strain images generated using the proposed technique. The tissue-mimicking phantom study results indicate that the proposed method is superior in improving image quality compared to the GLUE and SOUL techniques as it shows an average axial strain SNR and CNR improvement of 44% and 63%, and lateral strain SNR and CNR improvement of 130% and 435%, respectively. The results of the phantom study also indicate higher accuracy of displacement images obtained using the proposed technique, including improvement ranges of 7-84% and 26-140% for axial and lateral displacement images, respectively. For the clinical cases, the results indicate average improvement of 48% and 64% in SNR and CNR, respectively, in the axial strain images, and average improvement of 40% and 41% in SNR and CNR, respectively, in the lateral strain images. CONCLUSION: The proposed method is very effective in producing improved estimate of tissue displacement and strain images, especially with the lateral displacement and strain where the improvement is highly remarkable. While the method shows promise for clinical applications, further investigation is necessary for rigorous assessment of the method's performance in the clinic.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.908
Threshold uncertainty score0.970

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.311
Teacher spread0.293 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicUltrasound Imaging and ElastographyFrench-language works237,207