MétaCan
Menu
Back to cohort
Record W4309619646 · doi:10.1117/1.jbo.27.11.116005

Assessing jugular venous compliance with optical hemodynamic imaging by modulating intrathoracic pressure

2022· article· en· W4309619646 on OpenAlexafffund
Robert Amelard, Nyan Flannigan, Courtney A. Patterson, Hannah Heigold, Richard L. Hughson, Andrew D. Robertson

Bibliographic record

VenueJournal of Biomedical Optics · 2022
Typearticle
Languageen
FieldMedicine
TopicCerebral Venous Sinus Thrombosis
Canadian institutionsUniversity of WaterlooToronto Rehabilitation InstituteUniversity Health NetworkResearch Institute for Aging
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Space Agency
KeywordsCompliance (psychology)HemodynamicsOptical imagingMedicineBiomedical engineeringOpticsCardiology

Abstract

fetched live from OpenAlex

Significance: The internal jugular veins (IJV) are critical cerebral venous drainage pathways that are affected by right heart function. Cardiovascular disease and microgravity can alter central venous pressure (CVP) and venous return, which may contribute to increased intracranial pressure and decreased cardiac output. Assessing jugular venous compliance may provide insight into cerebral drainage and right heart function, but monitoring changes in vessel volume is challenging. Aim: We investigated the feasibility of quantifying jugular venous compliance from jugular venous attenuation (JVA), a noncontact optical measurement of blood volume, along with CVP from antecubital vein cannulation. Approach: CVP was progressively increased through a guided graded Valsalva maneuver, increasing mouth pressure by 2 mmHg every 2 s until a maximum expiratory pressure of 20 mmHg. JVA was extracted from a 1-cm segment between the clavicle and midneck. The contralateral IJV cross-sectional area (CSA) was measured with ultrasound to validate changes in the vessel size. Compliance was calculated using both JVA and CSA between four-beat averages over the duration of the maneuver. Results: JVA and CSA were strongly correlated (median and interquartile range) over the Valsalva maneuver across participants (r = 0.986, [0.983, 0.987]). CVP more than doubled on average between baseline and peak strain (10.7 ± 4.4 vs. 25.8 ± 5.4 cmH2O; p < 0.01). JVA and CSA increased nonlinearly with CVP, and both JVA- and CSA-derived compliance decreased progressively from baseline to peak strain (49% and 56% median reduction, respectively), with no significant difference in compliance reduction between the two measures (Z = - 1.24, p = 0.21). Pressure-volume curves showed a logarithmic relationship in both CSA and JVA. Conclusions: Optical jugular vein assessment may provide new ways to assess jugular distention and cardiac function.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.844
Threshold uncertainty score0.751

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.304
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomedical OpticsSame topicCerebral Venous Sinus ThrombosisFrench-language works237,207