MétaCan
Menu
Back to cohort
Record W4309722179 · doi:10.2495/eq-v7-n4-351-372

A review on the impact of building design and operation on buildings cooling loads

2022· review· en· W4309722179 on OpenAlexaff
Anaya Bara, Danlin Hou, Ibrahim Hassan, Liangzhu Wang, Mohammad Azizur Rahman

Bibliographic record

VenueInternational Journal of Energy Production and Management · 2022
Typereview
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsConcordia University
FundersQatar National Research FundFonds National de la Recherche LuxembourgQatar Foundation
KeywordsArchitectural engineeringEngineeringState (computer science)Building designCivil engineeringComputer science

Abstract

fetched live from OpenAlex

Energy consumption in buildings is considerably high in areas of hot and humid climates due to its association with high cooling loads. Electricity grids are highly affected by the consumption of cooling systems like air-conditioning and large refrigeration facilities, which significantly impact the economic and environmental sectors. As building design and operating parameters influence the cooling demand in the building, it is believed the root cause of the problem may be detected at an early building design stage. Thus, this review identifies the building design parameters that impact the cooling loads in buildings that are geographically restricted to countries with hot and humid climates. The building's design characteristics are classified into four main categories: glass characteristics, wall characteristics, building orientation and dimensions (BO & D), and building cooling system. The review was conducted over high-rise and low-rise buildings. Annual energy requirements (in some cases overlapping with electricity consumption), annual cooling loads, and peak cooling loads are the three forms in which energy demand reductions in buildings are represented. It is found that maximum annual cooling load savings are obtained through cooling systems, followed by wall characteristics, then glass characteristics, with the least for BO & D, with maximum reductions of up to 61%, 59%, 55%, and 21%, respectively. As for the peak cooling load reductions, wall characteristics, cooling systems, and glass characteristics had almost the same average values of 18.7%, 15.2%, and 17.2%, respectively, while BO & D are not reported due to the incomparable number of case studies. The parameters that have the most influence on reductions in peak cooling loads are wall and glass characteristics. In general, savings that are associated with wall characteristics are more significant for low-rise buildings than for high-rise buildings, while the latter is more influenced by glass characteristics. This is a reasonable conclusion since high-rise buildings, in general, acquire higher window-to-wall ratios than the former. In general, most studies considered glass characteristics, while fewer studies considered BO & D. This review has shown various aspects that are vital in studying building cooling load demand and its related energy performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.972
Threshold uncertainty score0.507

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.306
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Energy Production and ManagementSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207