MétaCan
Menu
Back to cohort
Record W4310361912 · doi:10.7759/cureus.32011

Comparison of Femoral Neck System Versus Cannulated Cancellous Screws for the Fixation of Femoral Neck Fracture in Young Adults: A Systematic Review and Meta-Analysis

2022· review· en· W4310361912 on OpenAlexaboutno aff
Govind Gupta, Arpita Rai, Subhankar P. Mandal, Sudha Rani, Shubhendu Shekhar, Subhajit Halder, Pancham Prasad, Amit Kumar, Zeya Ul Haque

Bibliographic record

VenueCureus · 2022
Typereview
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineFemoral neckHarris Hip ScoreCochrane LibrarySurgeryConfidence intervalMeta-analysisHip fractureFixation (population genetics)Randomized controlled trialOsteoporosisInternal medicineArthroplastyPopulation

Abstract

fetched live from OpenAlex

A femoral neck fracture is a very common injury in the elderly. However, its incidence is low among young adults, usually presenting as an emergency. In young adults, implant choice is one of the important factors. This systematic review aims to analyze the femoral neck system (FNS) versus cannulated cancellous (CC) screw for the fixation of femoral neck fractures in young adults through well-defined objectives. A comprehensive search from the electronic database (PubMed, Google Scholar, Web of Science, Cochrane Library) was conducted from the beginning till February 18, 2022. The data regarding study type, authors, year of publication, country, union time, Harris hip score, intraoperative blood loss, operating time, neck shortening, and hospital stay were extracted from the selected articles and analyzed using RevMan 5.4.1 software. For continuous data, e.g., healing time, intraoperative blood loss, operation time, Harris hip score, neck shortening, and hospital stay, the mean difference (MD), either weighted mean difference (WMD) or standardized mean difference (SMD), with a 95% confidence interval (CI) was recorded. A p-value less than 0.05 was taken as statistically significant. The Newcastle Ottawa scale was used for the risk of bias assessment. Six retrospective cohort studies including 427 patients were selected for the meta-analysis. There was significantly less healing time (WMD= -1.10, 95% CI: -1.73 to -0.47), shorter operation duration (WMD=7.70, 95% CI: -0.06 to 15.46), and better Harris hip score (WMD=4.79, 95% CI: 2.12-7.46) in the FNS than CC screw fixation method. However, intraoperative blood loss was significantly less in the CC screw system (WMD=21.27, 95% CI: 8.20-34.35). There was no significant difference between the two approaches in-hospital stay duration and femoral neck shortening. This can be concluded that FNS is better than CC screw fixation for treating neck of femur fractures in adults on the outcome basis of union time, less operation time, and better Harris hip score (HHS) with significant heterogeneity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.885
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0120.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.133
GPT teacher head0.410
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueCureusSame topicHip and Femur FracturesFrench-language works237,207