MétaCan
Menu
Back to cohort
Record W4310666182 · doi:10.1061/jaeied.aeeng-1410

Impact of Solar Mounting Systems on the Thermal Design of Commercial Roofs

2022· article· en· W4310666182 on OpenAlexaffabout
Sudhakar Molleti, Logan Carrigan, David van Reenen

Bibliographic record

VenueJournal of Architectural Engineering · 2022
Typearticle
Languageen
FieldEngineering
TopicBuilding Energy and Comfort Optimization
Canadian institutionsNational Research Council Canada
Fundersnot available
KeywordsPhotovoltaic systemBridging (networking)EngineeringThermalThermal resistanceInstallationEconomic shortageThermal comfortStructural engineeringEnvironmental scienceMechanical engineeringElectrical engineeringMeteorologyComputer science

Abstract

fetched live from OpenAlex

Commercial rooftops provide extensive areas representing the desired platform for installing photovoltaic (PV) systems. The combination of roofing assembly and PV system is called photovoltaic roofing assembly (PVRA). Currently, there is a shortage of information about building codes on PV system and roofing assembly integration. The National Research Council of Canada (NRC) developed an industry consortium project to generate codifiable research data on the wind and thermal performances of photovoltaic roofing assemblies. This paper examines the thermal bridging of the PV mounting attachments and its impact on the overall thermal resistance of the roofing assembly. Seven different types of PV mounting fixed attachments were tested in this study. Thermal bridging evaluation of PV mounts was done on the component level as individual mounts were installed through a section of a roofing assembly. The roofing assemblies were designed for a prescriptive thermal resistance of RSI 5.46 m2 K W−1 (R-31 h ft2 °F BTU−1) as per current standard and requirements for Climate zones 4–6. The thermal bridging experiments were conducted on a 1.2 m by 1.2 m guarded hot box at a mean temperature of 24°C. The measured data indicated a decrease in the effective thermal resistance of the PVRA, ranging from 3.3% to 50.0%, compared to the opaque roofing assembly devoid of any thermal bridging. Furthermore, it was found that among fastener-designed PV mounting attachments, the greater the number of fasteners, the more significant the decrease in effective thermal resistance. From the experimental data, chi factors (χ) were developed to support the calculation of point thermal bridging effects on the thermal performance of low-sloped roofing assemblies. Toward codification, efforts are underway to potentially implement these chi factors in the energy codes that could enhance the thermal design of both retrofit and new roof constructions installed with photovoltaic systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.195
Teacher spread0.184 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Architectural EngineeringSame topicBuilding Energy and Comfort OptimizationFrench-language works237,207