MétaCan
Menu
Back to cohort
Record W4310707371 · doi:10.1109/jtehm.2022.3214148

A Real-Time Endoscope Motion Tracker

2022· article· en· W4310707371 on OpenAlexafffund
Ian H. D. Phillips, David Armstrong, Qiyin Fang

Bibliographic record

VenueIEEE Journal of Translational Engineering in Health and Medicine · 2022
Typearticle
Languageen
FieldEngineering
TopicSoft Robotics and Applications
Canadian institutionsMcMaster University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Cancer Society Research Institute
KeywordsComputer visionEndoscopeComputer scienceMotion (physics)Artificial intelligenceComputer graphics (images)MedicineRadiology

Abstract

fetched live from OpenAlex

OBJECTIVE: In colonoscopy, it is desirable to accurately localize the position of the endoscope's distal tip. Current tip localization techniques are not sufficient for recording the position and movement of the tip, nor is its rotation measured. We hypothesize that integration of multiple tracking modalities can effectively record the endoscope's motion in real time and continuously corrects cumulative errors. METHODS: A dual modality tracking method is developed to measure the motion of the endoscope's insertion tube in real time, including insertion length, rotation angle, and their velocities. Optical trackballs were used to measure the endoscope insertion tube's motion and cameras were used to correct cumulative errors. RESULTS: The accuracy of insertion length and rotational angle were measured. For speeds ≤ 10 mm/s, the median and 90th percentile insertion position errors were 0.88 mm and 2.2 mm, respectively. The insertion position error increases with the speed, reaching a maximum of 10 mm for speeds < 40 mm/s. 11° and 21° were the median and 90th percentile rotation angle errors for angular speeds < 40°/s. Cumulative errors are sufficiently reduced by the imaging modality. CONCLUSION: The prototype device can precisely measure an unmodified endoscope's position, rotation, and motion in real time without significant accumulative error. The prototype device is small and compatible with existing commercial endoscopes as an add-on accessory, which could be used for reporting, localizing the lesions in follow up procedures, operational guidance, quality assurance, and training. Clinical and Translational Impact Statement-This preclinical research develops an endoscope tracker that can be integrated into colonoscopy training, automatically record endoscope motion, and be further developed to improve polyp and tumor localization during colonoscopy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.112
Threshold uncertainty score0.292

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.260
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Journal of Translational Engineering in Health and MedicineSame topicSoft Robotics and ApplicationsFrench-language works237,207