MétaCan
Menu
Back to cohort
Record W4311273061 · doi:10.29007/k9ms

Development of a Portable Upper Limb Muscle Dynamometer for Assessment of Neuromuscular Injury Patients

2022· article· en· W4311273061 on OpenAlexaff
Colin Day, Erik Bedard, Yassine El Alaoui, Mark I. Hwang, Michael Berger, Joshua W. Giles

Bibliographic record

VenueEPiC series in health sciences · 2022
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversity of British ColumbiaInternational Collaboration On Repair DiscoveriesUniversity of Victoria
Fundersnot available
KeywordsDynamometerIsometric exerciseRepeatabilityPhysical medicine and rehabilitationUpper limbPercentileElbowComputer sciencePhysical therapyMedicineBiomedical engineeringMathematicsSurgeryEngineeringAutomotive engineering

Abstract

fetched live from OpenAlex

Introduction Patient recovery from neuromuscular injuries that cause upper limb dysfunction is commonly assessed via manual methods. Manual muscle testing is subjective, time consuming and requires extensive training. Existing dynamometers are more objective, but they are prohibitively expensive and impractically large, making them inaccessible to most clinics and patients with disabilities. Our aim is to develop a table-top upper limb muscle dynamometer that provides standard positioning, ease of use and portability while giving clinicians consistent and reliable quantitative data on a patient’s isotonic and isometric muscle power and strength, respectively. Methods The device consists of a lever arm, a brushless DC motor, a load sensor and an ergonomic cuff. It outputs analog data via standard BNC connectors. The device can be intuitively controlled by the operator to test various upper limb joints and motions. Isometric measurement repeatability was assessed by recording the maximal voluntary contractions of 18 healthy participants over three trials. Results The repeatability across 3 trials was 2.70±2.27 Nm (95th percentile: 6.74 Nm) for elbow flexion, and 2.83±2.13 Nm (95th percentile: 5.65 Nm) for elbow extension. Conclusions The dynamometer demonstrates a marked improvement in repeatability relative to manual muscle testing. Its small footprint and low cost can make it an easily accessible, standardized testing tool that requires little training to use. Future research and development will focus on using field-oriented control to measure isotonic muscle power in addition to isometric strength.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.297
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueEPiC series in health sciencesSame topicMuscle activation and electromyography studiesFrench-language works237,207