MétaCan
Menu
← Back to cohort
Record W4311279532 · doi:10.1038/s41551-022-00971-6

An implantable soft robotic ventilator augments inspiration in a pig model of respiratory insufficiency

2022· article· en· W4311279532 on OpenAlexfundno aff
Lucy Hu, Jean Bonnemain, Mossab Y. Saeed, Manisha Singh, Diego Quevedo Moreno, Nikolay V. Vasilyev, Ellen T. Roche

Bibliographic record

VenueNature Biomedical Engineering · 2022
Typearticle
Languageen
FieldEngineering
TopicSoft Robotics and Applications
Canadian institutionsnot available
FundersCIHR Skin Research Training CentreNational Science FoundationCanadian Institutes of Health ResearchDivision of Chemical, Bioengineering, Environmental, and Transport SystemsNational Institute of Biomedical Imaging and BioengineeringDirectorate for EngineeringMuscular Dystrophy AssociationCentre Hospitalier Universitaire VaudoisNational Institutes of HealthU.S. Department of Health and Human ServicesGovernment of CanadaMassachusetts Institute of Technology
KeywordsRespiratory systemMedicineMechanical ventilatorIntensive care medicineCardiologyMechanical ventilationInternal medicine

Abstract

fetched live from OpenAlex

Abstract Severe diaphragm dysfunction can lead to respiratory failure, requiring permanent mechanical ventilation. Permanent tethering to a mechanical ventilator via a patient’s mouth or tracheostomy can interfere with quality of life and autonomy by hindering activities like speech and swallowing. We present a diaphragm assist system that intervenes internally at the diaphragm as opposed to the mouth. By implanting contractile, soft robotic actuators above the diaphragm to push downwards and augment diaphragm motion during inspiration, this diaphragm assist system functions as an implantable ventilator. We demonstrate the proof-of-concept feasibility of this system to augment physiological metrics of ventilation in an in vivo porcine model of varied respiratory insufficiency. Synchronized actuation of the assist system with native respiratory effort augmented the tidal volume by up to a 100 mL increase and was capable of improving minute ventilation into a normal range. The diaphragm assist system has the potential to provide a new therapeutic ventilation option that aims to restore respiratory performance without sacrificing quality of life.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.234
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations48
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueNature Biomedical Engineering→Same topicSoft Robotics and Applications→French-language works237,207→