MétaCan
Menu
Back to cohort
Record W4312065823 · doi:10.1002/mp.16176

Update of the CLRP Monte Carlo TG‐43 parameter database for high‐energy brachytherapy sources

2022· article· en· W4312065823 on OpenAlexafffund
Habib Safigholi, Marc Chamberland, R. E. P. Taylor, Martin P. Martinov, D. W. O. Rogers, Rowan M. Thomson

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsCarleton University
FundersOntario Ministry of Research and InnovationNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsMonte Carlo methodBrachytherapyComputer scienceComputational scienceDatabaseMedical physicsComputer graphics (images)Data miningPhysicsStatisticsMedicineRadiologyMathematicsRadiation therapy

Abstract

fetched live from OpenAlex

Abstract Purpose To update and extend version 2 of the Carleton Laboratory for Radiotherapy Physics (CLRP) TG‐43 dosimetry database ( CLRP_TG43v2 ) for high‐energy (HE, ≥50 keV) brachytherapy sources (1 169 Yb, 23 192 Ir, 5 137 Cs, and 4 60 Co) using egs_brachy , an open‐source EGSnrc application. A comprehensive dataset of TG‐43 parameters is compiled, including detailed source descriptions, dose‐rate constants, radial dose functions, 1D and 2D anisotropy functions, along‐away dose‐rate tables, Primary and Scatter Separated (PSS) dose tables, and mean photon energies escaping each source. The database also documents the source models which are freely distributed with egs_brachy . Acquisition and Validation Methods Datasets are calculated after a recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Air kerma per history is calculated in a 100.05 cm 3 voxel located 100 cm from the source along the transverse axis and then corrected for the lateral and thickness dimensions of the scoring voxel to give the air kerma on the central axis at a point 100 cm from the source's mid‐point. Full‐scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. Most data (except for 60 Co) are based on the assumption of charged particle equilibrium and ignore the potentially large effects of electron transport very close to the source and dose from initial beta particles. These effects are evaluated for four representative sources. For validation, data are compared to those from CLRP_TG43v1 and published data. Data Format and Access Data are available at https://physics.carleton.ca/clrp/egs_brachy/seed_database_v2 or http://doi.org/10.22215/clrp/tg43v2 including in Excel (.xlsx) spreadsheets, and are presented graphically in comparisons to previously published data for each source. Potential Applications The CLRP_TG43v2 database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more precise and in some cases more accurate Monte Carlo (MC) TG‐43 dose calculation parameters, as well as fully benchmarked and described source models which are distributed with egs_brachy .

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.693
Threshold uncertainty score0.610

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.265
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2022
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicRadiation Therapy and DosimetryFrench-language works237,207