MétaCan
Menu
Back to cohort
Record W4312114621 · doi:10.1186/s12890-022-02277-4

Tracheal airway pressure in tracheostomy tube capping trials: an experimental study

2022· article· en· W4312114621 on OpenAlexaff
Andreas Nowak, Sten Martin, Maik Höhne, Winfried Heller, Taras Usichenko, Eckart Klemm

Bibliographic record

VenueBMC Pulmonary Medicine · 2022
Typearticle
Languageen
FieldMedicine
TopicTracheal and airway disorders
Canadian institutionsMcMaster University
Fundersnot available
KeywordsTracheotomyCuffMedicinePressure dropTracheal tubeTube (container)AirwayStoma (medicine)Tracheostomy tubeIntubationAnesthesiaSurgeryMaterials scienceMechanicsComposite material

Abstract

fetched live from OpenAlex

BACKGROUND: Tracheostomy tube capping is a commonly used test to determine if the tracheostomy tube can be removed. The success of the capping trial depends on the patient's ability to maintain sufficient spontaneous breathing with an occluded tracheostomy tube. The impact of an occluded tracheotomy tube on airway resistance is currently unknown. The aim of this study was to investigate tracheal pressure during capping or stoma button insertion and potential determinants concerning cuff. METHODS: Eight cuffed and uncuffed tracheostomy tubes and three stoma buttons of various manufacturers and sizes were inserted into the trachea model. Cuffs were completely deflated or contained atmospheric pressure. The trachea was ventilated bidirectional with a respirator in volume-controlled mode and volume flows 15-60 L/min. Tracheal pressure drop during inspiration as a parameter of pressure required to move gas through the airway was measured. RESULTS: Tracheal pressure drops occurred linearly or irregularly during capping trials to a maximum of 4.2 kPa at flow rates of 60 L/min for atmospheric pressure cuffs. In tracheostomy tubes with completely deflated cuffs, pressure drop in the trachea reaches a maximum of 3.4 kPa at a flow rate of 60 L/min. For tracheostomy tubes with cuff smaller inner or outer diameters do not regularly result in lower tracheal pressure drop. The pressure drop varies between different tracheostomy tubes depending on the manufacturer. In cuffed tracheostomy tubes, we observed three phenomena: sail-like positioning, folding over, and tightening of the cuff during flow. The maximum tracheal pressure drop during stoma button insertion reaches 0.014 kPa. CONCLUSIONS: The cuff is a central element for the pressure drop in the airway and thus airway resistance during spontaneous translaryngeal breathing with a capped TT. Complete deflation reduces the pressure drop in the trachea. Due to deformation of the cuff, measured pressures are irregular as the volume flow is increased. Incomplete deflated cuffs and material characteristics of tracheostomy tubes and cuffs in addition to anatomical and clinical variables may cause unsuccessful capping trials due to increased airway resistance. All stoma buttons showed that pressure drop and thus airway resistance due to stoma buttons has no clinical relevance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.015

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0010.002
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.364
Teacher spread0.273 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueBMC Pulmonary MedicineSame topicTracheal and airway disordersFrench-language works237,207