Improved precision of SPECT myocardial blood flow using a net tracer retention model

2022· article· en· W4312129867 on OpenAlexaff
Sarah G. Cuddy‐Walsh, Robert A. deKemp, Terrence D. Ruddy, R. Glenn Wells

Bibliographic record

VenueMedical Physics · 2022
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsNuclear medicineCalibrationSingle-photon emission computed tomographyBlood flowMyocardial perfusion imagingCardiac PETSpect imagingEmission computed tomographyPositron emission tomographyPerfusionMathematicsMedicineStatisticsRadiology

Abstract

fetched live from OpenAlex

BACKGROUND: Noninvasive quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) provides incremental benefit to relative myocardial perfusion imaging (MPI) to diagnose and manage heart disease. MBF can be measured with single-photon emission computed tomography (SPECT) but the uncertainty in the measured values is high. Standardization and optimization of protocols for SPECT MBF measurements will improve the consistency of this technique. One element of the processing protocol is the choice of kinetic model used to analyze the dynamic image series. PURPOSE: This study evaluates if a net tracer retention model (RET) will provide a better fit to the acquired data and greater test-retest precision than a one-compartment model (1CM) for SPECT MBF, with (+MC) and without (-MC) manual motion correction. METHODS: Data from previously acquired rest-stress MBF studies (31 SPECT-PET and 30 SPECT-SPECT) were reprocessed ± MC. Rate constants (K1) were extracted using 1CM and RET, +/-MC, and compared pairwise with standard PET MBF measurements using cross-validation to obtain calibration parameters for converting SPECT rate constants to MBF and to assess the goodness-of-fit of the calibration curves. Precision (coefficient of variation of test re-test relative differences, COV) of flow measurements was computed for 1CM and RET ± MC using data from the repeated SPECT MBF studies. RESULTS: Both the RET model and MC improved the goodness-of-fit of the SPECT MBF calibration curves to PET. All models produced minimal bias compared with PET (mean bias < 0.6%). The SPECT-SPECT MBF COV significantly improved from 34% (1CM+MC) to 28% (RET+MC, P = 0.008). CONCLUSION: The RET+MC model provides a better calibration of SPECT to PET and blood flow measurements with better precision than the 1CM, without loss of accuracy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.054

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.015
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.279
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicCardiac Imaging and DiagnosticsFrench-language works237,207