Robotically-controlled three-dimensional micro-ultrasound for prostate biopsy guidance
Bibliographic record
Abstract
Abstract Purpose Prostate imaging to guide biopsy remains unsatisfactory, with current solutions suffering from high complexity and poor accuracy and reliability. One novel entrant into this field is microultrasound (microUS), which uses a high frequency imaging probe to achieve very high spatial resolution, and achieves prostate cancer detection rates equivalent to multiparametric magnetic resonance imaging (mpMRI). However, the ExactVu transrectal microUS probe has a unique geometry that makes it challenging to acquire controlled, repeatable three-dimensional (3D) transrectal ultrasound (TRUS) volumes. We describe the design, fabrication, and validation of a 3D acquisition system that allows for the accurate use of the ExactVu microUS device for volumetric prostate imaging. Methods The design uses a motorized, computer-controlled brachytherapy stepper to rotate the ExactVu transducer about its axis. We carry geometric validation using a phantom with known dimensions and we compare performance with magnetic resonance imaging (MRI) using a commercial quality assurance anthropomorphic prostate phantom. Results Our geometric validation shows accuracy of 1 mm or less in all three directions, and images of an anthropomorphic phantom qualitatively match those acquired using MRI and show good agreement quantitatively. Conclusion We describe the first system to acquire robotically- controlled 3D microUS images using the ExactVu microUS system. The reconstructed 3D microUS images are accurate, which will allow for applications of the ExactVu microUS system in prostate specimen and in vivo imaging.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".