MétaCan
Menu
Back to cohort
Record W4313452266 · doi:10.1088/1361-6498/acad0e

Eye-lens dose rate conversion factors due to hot particles and surface contaminations on the cornea

2022· article· en· W4313452266 on OpenAlexaff
J. Dubeau, S. Djeffal, Jiansheng Sun, Fawaz Ali

Bibliographic record

VenueJournal of Radiological Protection · 2022
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsCanadian Nuclear LaboratoriesCanadian Nuclear Safety CommissionPublic Works and Government Services Canada
Fundersnot available
KeywordsEye lensLens (geology)CataractsCorneaRadiation protectionDosimetryEquivalent doseRadionuclideEye protectionIonizing radiationOpticsEnvironmental scienceMedicineNuclear medicineOphthalmologyPhysicsIrradiationNuclear physics

Abstract

fetched live from OpenAlex

Abstract In 2012, the International Commission on Radiological Protection issued new recommendations, in publication 118, regarding the dose limits to the eye-lens. New analyses of historical exposure data had indicated that radiation-induced cataracts may appear at lower doses than previously assumed. This spurred largescale efforts in a variety of fields including dosimetry, radiation effects simulations, and the review of national regulatory limits. On the simulation side, much work led to the publication of dose rate conversion factors (DRCFs), to calculate the dose to the radiosensitive part of the eye-lens, and to the whole eye-lens as functions of the incident fluence of electron, photon, positron, and neutron radiation. The standard, ISO-15382 (2015 Radiological Protection—Procedures for Monitoring the Dose to the Lens of the Eye, the Skin and the Extremities ), from the International Organization for Standardization (ISO), stated that the direct contact of a hot radioactive particle on the eye-lens represents a special contamination condition that must be considered. The aim of this work was to produce tabulated data of eye-lens dose rates, per activity (MBq), for a variety of radionuclides. In this work, the dose to the eye-lens from contamination directly in contact with the cornea, expressed in terms of DRCFs for eye-lens, in units of Gy h −1 MBq −1 , are presented for 102 radionuclides of interest. These radionuclides were selected as they had been considered by the International Atomic Energy Agency of importance for skin dose. The method consisted of two steps. The first was the determination of the DRCFs for mono-energetic electrons and photons for a hot particle in contact with the eye-lens, followed by the folding of these quantities with the emissions of the radionuclides of interest. Contributions from spontaneous fission neutrons were considered separately. Exposure geometries for spherical hot particles of different dimensions, materials and locations on the cornea were considered. In addition, partial surface coverage of the cornea, consistent with an accidental exposure to a contaminated liquid, was also modelled. Resulting radionuclide DRCFs were verified, for a few specific geometries and radionuclides with dedicated Monte Carlo simulations. The final data are presented in several tables included in this paper.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.854
Threshold uncertainty score0.247

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.272
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2022
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Radiological ProtectionSame topicRadiation Dose and ImagingFrench-language works237,207