MétaCan
Menu
Back to cohort
Record W4316810417 · doi:10.1123/jmpb.2022-0031

The Stryd Foot Pod Is a Valid Measure of Stepping Cadence During Treadmill Walking and Running

2023· article· en· W4316810417 on OpenAlexaff
Madeline E. Shivgulam, Jennifer L. Petterson, Liam P. Pellerine, Derek S. Kimmerly, Myles W. O’Brien

Bibliographic record

VenueJournal for the Measurement of Physical Behaviour · 2023
Typearticle
Languageen
FieldMedicine
TopicPhysical Activity and Health
Canadian institutionsDalhousie University
Fundersnot available
KeywordsCadenceTreadmillEquivalence (formal languages)MathematicsSimulationPhysical medicine and rehabilitationComputer sciencePhysical therapyMedicine

Abstract

fetched live from OpenAlex

Stepping cadence is an important determinant of activity intensity, with faster stepping associated with the most health benefits. The Stryd monitor provides real-time feedback on stepping cadence. The limited existing literature has neither validated the Stryd across slow walking to fast running speeds nor strictly followed statistical guidelines for monitor validation studies. We assessed the criterion validity of the Stryd monitor to detect stepping cadence across multiple walking and jogging/running speeds. It was hypothesized that the Stryd monitor would be an accurate measure of stepping cadence across all measured speeds. Forty-six participants (23 ± 5 years, 26 females) wore the Stryd monitor on their shoelaces during a 10-stage progressive treadmill walking (Speeds 1–5) and jogging/running (Speeds 6–10) protocol (criterion: manually counted video-recorded cadence; total stages: 438). Standardized guidelines for physical activity monitor statistical analyses were followed. A two-way repeated-measure analysis of variance revealed the Stryd monitor recorded a slightly higher cadence (<1 steps/min difference, all p < .001) at 2 miles/hr (92.1 ± 6.2 steps/min vs. 91.5 ± 6.4 steps/min, p < .001), 2.5 miles/hr (101.3 ± 6.1 steps/min vs. 100.7 ± 6.4 steps/min), and 3.5 miles/hr (117.4 ± 5.9 steps/min vs. 117.0 ± 6.0 steps/min). However, equivalence testing demonstrated high equivalence of the Stryd and manually counted cadence (equivalence zone required: ≤± 2.6%) across all speeds. The Stryd activity monitor is a valid measure of stepping cadence across walking, jogging, and running speeds. By providing real-time cadence feedback, the Stryd monitor has strong potential to help guide the general public monitor their stepping intensity to promote more habitual activity at faster cadences.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.131
GPT teacher head0.367
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal for the Measurement of Physical BehaviourSame topicPhysical Activity and HealthFrench-language works237,207