MétaCan
Menu
Back to cohort
Record W4316927993 · doi:10.1111/jopr.13649

Strains in the implant collars supporting a cantilevered cross‐arch bar prosthesis. An in vitro study

2023· article· en· W4316927993 on OpenAlexaff
Rakan Baaj, Maryam Khalili, Allyn Luke, Saul Weiner

Bibliographic record

VenueJournal of Prosthodontics · 2023
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsImplantMaterials scienceStrain gaugeCantileverCollarProsthesisArchStrain (injury)Biomedical engineeringOrthodonticsStructural engineeringAnatomyComposite materialMedicineSurgeryEngineering

Abstract

fetched live from OpenAlex

PURPOSE: To examine the strains in the collar area of implants supporting a cantilevered cross-arch bar prosthesis during vertical load application. MATERIALS AND METHODS: A milled cross-arch metal framework supported by four implants in a trapezoidal design was supported in polymethylmethacrylate. T-strain gage rosettes were attached to the crestal areas of the implants with two grids, one recording circumference strain of the crestal area of the implant and the second recording vertical strain, torquing strains of the implant. The framework was subject to vertical loading from an MTS 810 mechanical system. Loading sites were directly on anterior and posterior implants, and on a cantilever at 7.5, 15, 22.5, and 30 mm (0.5, 1.0, 1.5, and 2.0 of the anterior-posterior spread) distal from the posterior implant on the right side. The anterior-posterior (A-P) spread from anterior to posterior implants was 15 mm. Sites were loaded individually with 50 and 100 N. The data from the rosettes were transferred to a desktop computer and processed using StrainSmart 5000 software. RESULTS: Means and standard deviations were calculated for the 10 trials at each of the loading sites. Two-way ANOVAs were done separately for each dependent variable, the vertical grid, and the circumferential grid. The independent variables were the load magnitude and the load site. Tukey's test was used to compare groups post hoc. When directly loading the implants, loading the anterior implant resulted initially in compression followed by increasing tensile strain with 100 N loads. Loading the implant adjacent to cantilever (the posterior implant) resulted in greater strain at the collar than that observed with anterior implant with minimal bending strains. When loading the cantilever, anterior implant showed increasing bending strain at greater cantilever length, whereas the circumferential strains were greater for the supporting implant adjacent to the cantilever, particularly at 100 N loads, p ≤ 0.001. CONCLUSIONS: Limiting cantilever lengths to A-P spread ratios of 0.5 are preferred. Ratios greater than 1.0 should be avoided as flexing of the collar may occur. The dimensions of the implant, particularly wall thickness, adjacent to the cantilever should be carefully considered when planning the cantilevered implant-supported prosthesis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.055
Threshold uncertainty score0.617

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.072
GPT teacher head0.407
Teacher spread0.335 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ProsthodonticsSame topicDental Implant Techniques and OutcomesFrench-language works237,207