MétaCan
Menu
Back to cohort
Record W4317712964 · doi:10.1186/s12968-023-00917-0

Myocardial late gadolinium enhancement using delayed 3D IR-FLASH in the pediatric population: feasibility and diagnostic performance compared to single-shot PSIR-bSSFP

2023· article· en· W4317712964 on OpenAlexaff
Ankavipar Saprungruang, Julien Aguet, Navjot Gill, Vivian P. Tassos, Afsaneh Amirabadi, Mike Seed, Shi‐Joon Yoo, Christopher Z. Lam

Bibliographic record

VenueJournal of Cardiovascular Magnetic Resonance · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsSickKids FoundationUniversity of TorontoHospital for Sick Children
Fundersnot available
KeywordsMedicineAngiologyGadoliniumFlash (photography)Single shotShot (pellet)PopulationMedical physicsInternal medicineOpticsEnvironmental health

Abstract

fetched live from OpenAlex

BACKGROUND: This study compares three-dimensional (3D) high-resolution (HR) late gadolinium enhancement (LGE; 3D HR-LGE) imaging using a respiratory navigated, electrocardiographically-gated inversion recovery gradient echo sequence with conventional LGE imaging using a single-shot phase-sensitive inversion recovery (PSIR) balanced steady-state free precession (bSSFP; PSIR-bSSFP) sequence for routine clinical use in the pediatric population. METHODS: Pediatric patients (0-18 years) who underwent clinical cardiovascular magnetic resonance (CMR) with both 3D HR-LGE and single-shot PSIR-bSSFP LGE between January 2018 and June 2020 were included. Image quality (0-4) and detection of LGE in the left ventricle (LV) (per 17 segments), in the right ventricle (RV) (per 3 segments), as endocardial fibroelastosis (EFE), at the hinge points, and at the papillary muscles was analyzed by two blinded readers for each sequence. Ratios of the mean signal intensity of LGE to normal myocardium (LGE:Myo) and to LV blood pool (LGE:Blood) were recorded. Data is presented as median (1st-3rd quartiles). Wilcoxon signed rank test and chi-square analyses were used as appropriate. Inter-rater agreement was analyzed using weighted κ-statistics. RESULTS: 102 patients were included with median age at CMR of 8 (1-13) years-old and 44% of exams performed under general anesthesia. LGE was detected in 55% of cases. 3D HR LGE compared to single-shot PSIR-bSSFP had longer scan time [4:30 (3:35-5:34) vs 1:11 (0:47-1:32) minutes, p < 0.001], higher image quality ratings [3 (3-4) vs 2 (2-3), p < 0.001], higher LGE:Myo [23.7 (16.9-31.2) vs 5.0 (2.9-9.0), p < 0.001], detected more segments of LGE in both the LV [4 (2-8) vs 3 (1-7), p = 0.045] and RV [1 (1-1) vs 1 (0-1), p < 0.001], and also detected more cases of LGE with 13/56 (23%) of patients with LGE only detectable by 3D HR LGE (p < 0.001). 3D HR LGE specifically detected a greater proportion of RV LGE (27/27 vs 17/27, p < 0.001), EFE (11/11 vs 5/11, p = 0.004), and papillary muscle LGE (14/15 vs 4/15, p < 0.001). Inter-rater agreement for the recorded variables ranged from 0.42 to 1.00. CONCLUSIONS: 3D HR LGE achieves greater image quality and detects more LGE than conventional single-shot PSIR-bSSFP LGE imaging, and should be considered an alternative to conventional LGE sequences for routine clinical use in the pediatric population.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.077
Threshold uncertainty score0.879

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.286
Teacher spread0.241 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicCardiac Imaging and DiagnosticsFrench-language works237,207