MétaCan
Menu
Back to cohort
Record W4318483792 · doi:10.1038/s41598-023-27596-2

In-situ synchrotron quantitative analysis of competitive adsorption tendency of human serum proteins on polyether sulfone clinical hemodialysis membrane

2023· article· en· W4318483792 on OpenAlexafffundabout
Amira Abdelrasoul, Ning Zhu, Huu Doan, Ahmed Shoker

Bibliographic record

VenueScientific Reports · 2023
Typearticle
Languageen
FieldMedicine
TopicBlood properties and coagulation
Canadian institutionsSt. Paul's HospitalToronto Metropolitan UniversityCanadian Light Source (Canada)University of Saskatchewan
FundersCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaSaskatchewan Health Research FoundationUniversity of SaskatchewanCanadian Light Source
KeywordsAdsorptionHuman serum albuminChemistryDialysisProtein adsorptionHemodialysisMembraneQuantitative analysis (chemistry)Serum albuminBlood proteinsChromatographyDialysis tubingBiophysicsBiochemistryMedicineSurgeryBiologyOrganic chemistry

Abstract

fetched live from OpenAlex

Comprehensive understanding of protein adsorption phenomenon on membrane surface during hemodialysis (HD) is one of the key moments for development of hemocompatible HD membrane. Though many mechanisms and kinetics of protein adsorption on some surface have been studied, we are still far away from complete understanding and control of this process, which results in a series of biochemical reactions that causes severe complications with health and even the death among HD patients. The aim of this study is to conduct quantitative analysis of competitive adsorption tendency of human serum protein on polyether sulfone (PES) clinical dialysis membrane. In situ synchrotron radiation micro-computed tomography (SR-µCT) imaging available at the Canadian Light Source (CLS) was conducted to assess human serum proteinbinding and undertake the corresponding quantitative analysis.The competitive adsorption of Human protein albumin (HSA), fibrinogen (FB) and transferrin (TRF) were tested from single and multiple protein solution. Furthermore, in-vitro human serum protein adsorption on clinical dialyzers was investigated using UV-Visible to confirm the competitive adsorption tendency. Results showed that when proteins were adsorbed from their mixture, FB content (among proteins) in the adsorbed layer increased from 3.6% mass (content in the initial solution) to 18% mass and 12%, in case of in situ quantitative and invitro analysis, respectively. The increase in FB content was accompanied by the decrease in the HSA content, while TRF remained on approximately on the same level for both cases. Overall, the percentage of HSA adsorption ratio onto the HD membrane has dropped approximately 10 times when HSA was adsorbed in competition with other proteins, compared to the adsorption from single HSA solution. The substitution of HSA with FB was especially noticeable when HSA adsorption from its single solution was compared with the case of the protein mixture. Moreover, SR-µCT has revealed that FB when adsorbed from a protein mixture solution is located predominately in the middle of the membrane, whereas the peak of the distribution is shifted to membrane bottom layers when adsorption from FB single solution takes place. Results showed that HSA FB and TRF adsorption behavior observations are similar on both in-situ small scale and clinical dialyzer of the PES membrane.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.550
Threshold uncertainty score0.429

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.003
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.057
GPT teacher head0.357
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2023
Admission routes3
Has abstractyes

Explore more

Same venueScientific ReportsSame topicBlood properties and coagulationFrench-language works237,207