Contribution of the Provençal Well for the Improvement of the Thermal Comfort in the Building in Turbulent Regime
Bibliographic record
Abstract
In the current energy context, geothermal systems are highly developed in the building field. Among these interesting systems on the energy plan, one finds in particular the earth-to-air heat exchanger commonly called ‘Canadian or Provençal well’. It consists of tubes buried in which the ambient air is pushed in order to be refreshed in contact with the ground whose temperature is quasi-constant throughout the year. In this work, a study of the performance of an earth-to-air heat exchanger was undertaken by means of numerical modeling of heat exchange by forced convection in a buried tube. The transfer equations in the tube are discretized using the finite volume method in turbulent regime and solved using the Thomas algorithm. For the determination of the ground temperature, the model of the semi-infinite mass subjected to a periodic excitation was adopted. The soil temperature was used as a boundary condition for the buried tube. The results show that the interest of the earth-to-air heat exchanger is major, since it improves throughout the year, the thermal conditions sought. It intervenes in an effective way on the damping of the thermal amplitudes in the building. The variation of the diameter and the length of earth-to-air heat exchanger does not influence notably the distribution of the streamlines and isotherms but affect significantly the values of stream function and temperature inside de tube of the earth-to-air heat exchanger. When diameter of the pipe increases, the outlet temperature increases. The increase of the length of the earth-to-air heat exchanger leads to the isotherms increase as a result of the intensification of heat exchange between the walls and the convective jet. The temperature in the air outlet compartment is lower as the length of the earth-to-air exchanger increases.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".