MétaCan
Menu
Back to cohort
Record W4319663853 · doi:10.3138/ptc-2021-0016

Muscle Architecture and Subcutaneous Fat Measurements of Rectus Femoris and Vastus Lateralis at Optimal Length Aided by a Novel Ultrasound Transducer Attachment

2023· article· en· W4319663853 on OpenAlexaffvenue
Brittany D. Bulbrook, Jaclyn N. Chopp‐Hurley, Emily G. Wiebenga, Janet M. Pritchard, Anthony A. Gatti, Peter J. Keir, Monica R. Maly

Bibliographic record

VenuePhysiotherapy Canada · 2023
Typearticle
Languageen
FieldEngineering
TopicLower Extremity Biomechanics and Pathologies
Canadian institutionsUniversity of WaterlooYork UniversityMcMaster University
Fundersnot available
KeywordsTransducerUltrasoundTilt (camera)MedicineMuscle architectureRepeatabilityBiomedical engineeringIntra-rater reliabilityRectus femoris muscleMaterials scienceAnatomyNuclear medicineElectromyographyAcousticsRadiologyPhysical medicine and rehabilitationMathematicsPhysics

Abstract

fetched live from OpenAlex

Purpose: This cross-sectional study determines the sensitivity of muscle architecture and fat measurements of the rectus femoris (RF) and vastus lateralis (VL) muscles from ultrasound images acquired with varying transducer tilt, using a novel transducer attachment, in healthy adults. Secondary objectives were to estimate intrarater and interrater reliability of image measurement and acquisition, respectively. Methods: Thirty healthy adults participated (15 women and 15 men; 25 [SD 2.5] y). Ultrasound image acquisition was conducted by two raters at different transducer tilts relative to the skin: estimated perpendicular, and five measured angles (80°, 85°, 90°, 95°, 100°) using the transducer attachment. Muscle thickness (MT), subcutaneous fat thickness (FT), pennation angle (PA), and fascicle length (FL) were measured. Sensitivity and reliability were assessed using intra-class correlation coefficients (ICCs) and standard error of measurements (SEMs). Results: MT and FT for RF and VL were not sensitive to transducer tilt. However, PA and FL were sensitive to transducer tilt. MT and FT for both muscles showed high ICCs and low SEMs for intrarater and interrater reliability. For PA of both muscles, standardizing transducer tilt improved interrater ICCs and lowered SEMs. Conclusion: MT and FT measurements of RF and VL acquired at 60° knee flexion are robust to varying transducer tilt angles. PA measurements benefit from standardizing transducer tilt.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.093
Threshold uncertainty score0.967

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.222
Teacher spread0.207 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2023
Admission routes2
Has abstractyes

Explore more

Same venuePhysiotherapy CanadaSame topicLower Extremity Biomechanics and PathologiesFrench-language works237,207