MétaCan
Menu
Back to cohort
Record W4319966076 · doi:10.1302/1358-992x.2023.2.014

LONG-TERM RESULTS OF A NEW ROTATING HINGE KNEE IMPLANT: A MINIMUM SEVEN-YEAR FOLLOW-UP

2023· article· en· W4319966076 on OpenAlexaboutno aff
Klemens Vertesich, Kevin Staats, Ch. Böhler, Richard Koza, Richard Lass, A. Giurea

Bibliographic record

VenueOrthopaedic Proceedings · 2023
Typearticle
Languageen
FieldMedicine
TopicTotal Knee Arthroplasty Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineProsthesisProthesisSurgeryWOMACOsteoarthritisRange of motionArthroplastyImplantOrthopedic surgeryCumulative incidenceTransplantation

Abstract

fetched live from OpenAlex

The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty. Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode. KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002). The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.074
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.274
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more