Safety and efficacy of target controlled infusion administration of propofol and remifentanil for moderate sedation in non-hospital dental practice
Bibliographic record
Abstract
Background: Fearful and anxious patients who find dental treatment intolerable without sedative and analgesic support may benefit from moderate sedation. Target controlled infusion (TCI) pumps are superior to bolus injection in maintaining low plasma and effect-site concentration variability, resulting in stable, steady-state drug concentrations. We evaluated the safety and efficacy of moderate sedation with remifentanil and propofol using TCI pumps in non-hospital dental settings. Methods: A prospective chart review was conducted on 101 patients sedated with propofol and remifentanil using TCI pumps. The charts were completed at two oral surgeons and one general dentist's office over 6 months. Hypoxia, hypotension, bradycardia, and over-sedation were considered adverse events and were collected using Tracking and Reporting Outcomes of Procedural Sedation (TROOPS). Furthermore, patient recovery time, sedation length, drug dose, and patient satisfaction questionnaires were used to measure sedation effectiveness. Results: Of the 101 reviewed sedation charts, 54 were of men, and 47 were of women. The mean age of the patients was 40.5 ±18.7 years, and their mean BMI was 25.6 ± 4.4. The patients did not experience hypoxia, bradycardia, and hypotension during the 4694 min of sedation. The average minimum Mean Arterial Pressure (MAP) and heartbeats were 75.1 mmHg and 60.4 bpm, respectively. 98% of patients agreed that the sedation technique met their needs in reducing their anxiety, and 99% agreed that they were satisfied with the sedation 24 hours later. The average sedation time was 46.9 ± 55.6 min, and the average recovery time was 12.4 ± 4.4 min. Remifentanil and propofol had mean initial effect-site concentration doses of 0.96 µ/ml and 1.0 ng/ml respectively. The overall total amount of drug administered was significantly higher in longer sedation procedures compared to shorter ones, while the infusion rate decreased as the procedural stimulus decreased. Conclusion: According to the results of this study, no patients experienced adverse events during sedation, and all patients were kept at a moderate sedation level for a wide range of sedation times and differing procedures. The results showed that TCI pumps are safe and effective for administering propofol and remifentanil for moderate sedation in dentistry.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".