Development of an Open-source and Lightweight Sensor Recording Software System for Conducting Biomedical Research: Technical Report
Bibliographic record
Abstract
BACKGROUND: Digital sensing devices have become an increasingly important component of modern biomedical research, as they help provide objective insights into individuals' everyday behavior in terms of changes in motor and nonmotor symptoms. However, there are significant barriers to the adoption of sensor-enhanced biomedical solutions in terms of both technical expertise and associated costs. The currently available solutions neither allow easy integration of custom sensing devices nor offer a practicable methodology in cases of limited resources. This has become particularly relevant, given the need for real-time sensor data that could help lower health care costs by reducing the frequency of clinical assessments performed by specialists and improve access to health assessments (eg, for people living in remote areas or older adults living at home). OBJECTIVE: The objective of this paper is to detail the end-to-end development of a novel sensor recording software system that supports the integration of heterogeneous sensor technologies, runs as an on-demand service on consumer-grade hardware to build sensor systems, and can be easily used to reliably record longitudinal sensor measurements in research settings. METHODS: The proposed software system is based on a server-client architecture, consisting of multiple self-contained microservices that communicated with each other (eg, the web server transfers data to a database instance) and were implemented as Docker containers. The design of the software is based on state-of-the-art open-source technologies (eg, Node.js or MongoDB), which fulfill nonfunctional requirements and reduce associated costs. A series of programs to facilitate the use of the software were documented. To demonstrate performance, the software was tested in 3 studies (2 gait studies and 1 behavioral study assessing activities of daily living) that ran between 2 and 225 days, with a total of 114 participants. We used descriptive statistics to evaluate longitudinal measurements for reliability, error rates, throughput rates, latency, and usability (with the System Usability Scale [SUS] and the Post-Study System Usability Questionnaire [PSSUQ]). RESULTS: Three qualitative features (event annotation program, sample delay analysis program, and monitoring dashboard) were elaborated and realized as integrated programs. Our quantitative findings demonstrate that the system operates reliably on consumer-grade hardware, even across multiple months (>420 days), providing high throughput (2000 requests per second) with a low latency and error rate (<0.002%). In addition, the results of the usability tests indicate that the system is effective, efficient, and satisfactory to use (mean usability ratings for the SUS and PSSUQ were 89.5 and 1.62, respectively). CONCLUSIONS: Overall, this sensor recording software could be leveraged to test sensor devices, as well as to develop and validate algorithms that are able to extract digital measures (eg, gait parameters or actigraphy). The proposed software could help significantly reduce barriers related to sensor-enhanced biomedical research and allow researchers to focus on the research questions at hand rather than on developing recording technologies.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.023 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.003 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.002 |
| Open science | 0.002 | 0.003 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.