MétaCan
Menu
Back to cohort
Record W4322773007 · doi:10.1364/boe.485824

Hybrid silicon-tellurium-dioxide DBR resonators coated in PMMA for biological sensing

2023· article· en· W4322773007 on OpenAlexafffund
Dawson B. Bonneville, Mitchell Albert, Ramis Arbi, Muhammad Munir, Bruno L. Segat Frare, Khadijeh Miarabbas Kiani, Henry C. Frankis, Andrew P. Knights, Ayse Turak, Kyla N. Sask, Jonathan D. B. Bradley

Bibliographic record

VenueBiomedical Optics Express · 2023
Typearticle
Languageen
FieldEngineering
TopicPhotonic and Optical Devices
Canadian institutionsMcMaster University
FundersOntario Ministry of Research and InnovationNatural Sciences and Engineering Research Council of CanadaCanada Foundation for InnovationMcMaster UniversityCMC Microsystems
KeywordsSilicon dioxideMaterials scienceTelluriumResonatorSiliconOptoelectronicsOpticsNanotechnologyComposite material

Abstract

fetched live from OpenAlex

We report on silicon waveguide distributed Bragg reflector (DBR) cavities hybridized with a tellurium dioxide (TeO 2 ) cladding and coated in plasma functionalized poly (methyl methacrylate) (PMMA) for label free biological sensors. We describe the device structure and fabrication steps, including reactive sputtering of TeO 2 and spin coating and plasma functionalization of PMMA on foundry processed Si chips, as well as the characterization of two DBR designs via thermal, water, and bovine serum albumin (BSA) protein sensing. Plasma treatment on the PMMA films was shown to decrease the water droplet contact angle from ∼70 to ∼35°, increasing hydrophilicity for liquid sensing, while adding functional groups on the surface of the sensors intended to assist with immobilization of BSA molecules. Thermal, water and protein sensing were demonstrated on two DBR designs, including waveguide-connected sidewall (SW) and waveguide-adjacent multi-piece (MP) gratings. Limits of detection of 60 and 300 × 10 −4 RIU were measured via water sensing, and thermal sensitivities of 0.11 and 0.13 nm/°C were measured from 25–50 °C for SW and MP DBR cavities, respectively. Plasma treatment was shown to enable protein immobilization and sensing of BSA molecules at a concentration of 2 µg/mL diluted in phosphate buffered saline, demonstrating a ∼1.6 nm resonance shift and subsequent full recovery to baseline after stripping the proteins with sodium dodecyl sulfate for a MP DBR device. These results are a promising step towards active and laser-based sensors using rare-earth-doped TeO 2 in silicon photonic circuits, which can be subsequently coated in PMMA and functionalized via plasma treatment for label free biological sensing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.841
Threshold uncertainty score0.812

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.252
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueBiomedical Optics ExpressSame topicPhotonic and Optical DevicesFrench-language works237,207