MétaCan
Menu
Back to cohort
Record W4328048716 · doi:10.1038/s41598-023-31637-1

Evaluation of transcutaneous near-infrared spectroscopy for early detection of cardiac arrest in an animal model

2023· article· en· W4328048716 on OpenAlexafffund
Katharina Raschdorf, Arman Mohseni, Kaavya Hogle, Amanda Cheung, Kitty So, Neda Manouchehri, Mahsa Khalili, Saud Lingawi, Brian Grunau, Calvin Kuo, Jim Christenson, Babak Shadgan

Bibliographic record

VenueScientific Reports · 2023
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsUniversity of British Columbia HospitalSt. Paul's HospitalInternational Collaboration On Repair DiscoveriesUniversity of British Columbia
FundersMichael Smith Health Research BCU.S. Department of Defense
KeywordsMedicineBlood pressureHemodynamicsAnesthesiaOxygen saturationResuscitationPentobarbitalCardiologyCardiopulmonary resuscitationInternal medicineOxygen

Abstract

fetched live from OpenAlex

Abstract Sudden cardiac arrest (SCA) is a leading cause of mortality worldwide. The SCA-to-resuscitation interval is a key determinant of patient outcomes, highlighting the clinical need for reliable and timely detection of SCA. Near-infrared spectroscopy (NIRS), a non-invasive optical technique, may have utility for this application. We investigated transcutaneous NIRS as a method to detect pentobarbital-induced changes during cardiac arrest in eight Yucatan miniature pigs. NIRS measurements during cardiac arrest were compared to invasively acquired carotid blood pressure and partial oxygen pressure (PO 2 ) of spinal cord tissues. We observed statistically significant decreases in mean arterial pressure (MAP) 64.68 mmHg ± 13.08, p < 0.0001), spinal cord PO 2 (38.16 mmHg ± 20.04, p = 0.0028), and NIRS-derived tissue oxygen saturation (TSI%) (14.50% ± 3.80, p < 0.0001) from baseline to 5 min after pentobarbital administration. Euthanasia-to-first change in hemodynamics for MAP and TSI (%) were similar [MAP (10.43 ± 4.73 s) vs TSI (%) (12.04 ± 1.85 s), p = 0.3714]. No significant difference was detected between NIRS and blood pressure-derived pulse rates during baseline periods ( p > 0.99) and following pentobarbital administration ( p = 0.97). Transcutaneous NIRS demonstrated the potential to identify rapid hemodynamic changes due to cardiac arrest in periods similar to invasive indices. We conclude that transcutaneous NIRS monitoring may present a novel, non-invasive approach for SCA detection, which warrants further investigation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.097
Threshold uncertainty score0.459

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.278
Teacher spread0.248 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueScientific ReportsSame topicNon-Invasive Vital Sign MonitoringFrench-language works237,207