The incidence of spontaneous arrhythmias in telemetered beagle dogs, Göttingen Minipigs and Cynomolgus non-human primates: A HESI consortium retrospective analysis

2023· article· en· W4353046727 on OpenAlexaff
Emmanuel Boulay, Loïs S. Miraucourt, Michael K. Pugsley, Matthew M. Abernathy, Ray W. Chui, Jill A. Dalton, Marjorie Demers, Noël Dybdal, Elissa Gazaille, Andrea Greiter‐Wilke, Peter Hoffmann, Hai Huang, Carrie LaDuke, Kevin Norton, Jennifer Pierson, Isabelle Reeves, Brian Roche, Eric I. Rossman, A. Eric Schultze, Hai-Ming Tang, Todd Wisialowski, Simon Authier

Bibliographic record

VenueJournal of Pharmacological and Toxicological Methods · 2023
Typearticle
Languageen
FieldMedicine
TopicCardiac electrophysiology and arrhythmias
Canadian institutionsUniversité de Montréal
Fundersnot available
KeywordsBigeminyBeagleMedicineIncidence (geometry)Ventricular tachycardiaTelemetryVentricular fibrillationCardiologyInternal medicineSafety pharmacologyAnesthesiaPharmacologyDrug

Abstract

fetched live from OpenAlex

INTRODUCTION: Characterization of the incidence of spontaneous arrhythmias to identify possible drug-related effects is often an important part of the analysis in safety pharmacology studies using telemetry. METHODS: A retrospective analysis in non-clinical species with and without telemetry transmitters was conducted. Electrocardiograms (24 h) from male and female beagle dogs (n = 131), Göttingen minipigs (n = 108) and cynomolgus non-human primates (NHP; n = 78) were analyzed. RESULTS: Ventricular tachycardia (VT) was observed in 3% of the dogs but was absent in minipigs and NHPs. Ventricular fibrillation (VF) was not observed in the 3 species. Ventricular premature beats (VPBs) were more frequent during daytime and atrioventricular blocks (AVBs) were more frequent at night in all species. A limited number of animals exhibited a high arrhythmia frequency and there was no correlation between animals with higher frequency of an arrhythmia type and the frequency of other arrythmias in the same animals. Clinical chemistry or hematology parameters were not different with or without telemetry devices. NHP with a transmural left ventricular pressure (LVP) catheter exhibited a greater incidence of VPBs and PJCs compared to telemetry animals without LVP. DISCUSSION: All species were similar with regards to the frequency of ventricular ectopic beats (26-46%) while the dog seemed to have more frequent junctional complexes and AVB compared to NHP and minipigs. Arrhythmia screening may be considered during pre-study evaluations, to exclude animals with abnormally high arrhythmia incidence.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.892
Threshold uncertainty score0.513

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.399
Teacher spread0.369 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Pharmacological and Toxicological MethodsSame topicCardiac electrophysiology and arrhythmiasFrench-language works237,207