MétaCan
Menu
Back to cohort
Record W4361195714 · doi:10.1177/2325967123s00016

Paper 16: The Use of Intravenous Tranexamic Acid Does Not Improve Arthroscopic Visualization in Shoulder Surgery: A Randomized Controlled Trial

2023· article· en· W4361195714 on OpenAlexaff
Jason Old, Thomas Suter, Sheila McRae, Yiyang Zhang, Jarret M. Woodmass, Thomas C. Mutter, Scott W. Wolfe, Jon N. Marsh, James Dubberley, Peter MacDonald

Bibliographic record

VenueOrthopaedic Journal of Sports Medicine · 2023
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsUniversity of ManitobaPan Am Clinic
Fundersnot available
KeywordsMedicineTranexamic acidRandomized controlled trialEpinephrineVisual analogue scaleAnesthesiaSurgeryArthroscopyShoulder surgeryRotator cuff

Abstract

fetched live from OpenAlex

Objectives: Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon’s visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is an effective alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. Methods: The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. Unweighted means (SD) were calculated for visualization and mean arterial pressure (MAP) for each patient. Study group allocation was represented with epinephrine and tranexamic acid being coded in dichotomous variables (used or not used) for each patient. A step-wise linear regression was performed using visualization as the dependent variable and a series of independent variables considered for inclusion: epinephrine, tranexamic acid, surgery duration, complexity, mean arterial pressure, increase in pump pressure, and volume of irrigation fluid. All statistical tests were considered significant if p<0.05. Results: One-hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Figure 1 presents the patient flow through the study. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p<0.001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p<0.001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Conclusions: Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone. [Figure: see text]

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.074

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.009
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0070.004
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0030.002
Open science0.0020.001
Research integrity0.0050.004
Insufficient payload (model declined to judge)0.0220.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.309
Teacher spread0.277 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueOrthopaedic Journal of Sports MedicineSame topicShoulder Injury and TreatmentFrench-language works237,207