MétaCan
Menu
Back to cohort
Record W4362694178 · doi:10.1117/12.2652983

Experimental optimization of photon-counting dual-energy thoracic imaging

2023· article· en· W4362694178 on OpenAlexaff
Jeffrey Dhari, Jesse Tanguay

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsToronto Metropolitan University
Fundersnot available
KeywordsImaging phantomVoltageMaterials scienceNoise (video)Energy (signal processing)PhotonOpticsAttenuationTube (container)Photon energyPhysicsOptoelectronicsBiomedical engineeringComputer scienceMedicine

Abstract

fetched live from OpenAlex

Dual-energy (DE) thoracic imaging with photon counting detectors (PCDs) enables suppressing anatomic noise due to bone structures, potentially improving the detection of lung nodules. Relative to DE approaches based on the kV-switching method, a PCD-based, single-exposure approach may reduce the potential for motion artifacts and suppress electronic noise. In this work, we experimentally optimize the energy thresholds and tube voltages for single-exposure DE thoracic imaging implemented with PCDs. We used a phantom consisting of uniform acrylic slabs totaling 8.6 cm in thickness with a 16 cm air gap between slabs. A lung nodule was simulated by adding 2 mm of acrylic in a small region of interest in the center of the phantom. We imaged the phantom using a PCD with a 750-μm-thick cadmium telluride x-ray convertor, 100×100 μm2 detector elements, two user-defined energy thresholds, and analog charge summing for charge sharing correction. We acquire images for tube voltages ranging from 90 kV to 130 kV in 10-kV increments. For each tube voltage, we varied the energy threshold from 32 keV to 90% of the maximum beam energy. The contrast-to-noise ratio (CNR) of the simulated nodule was measured for each combination of tube voltage and energy threshold. Optimal energy thresholds range from 45 keV to 55 keV for tube voltages ranging from 110 kV to 120 kV. When optimized for the energy thresholds, there was relatively little variability in the CNR across tube voltages beyond that due to measurement error. Future work will compare the CNR of PCD-based DE radiography with the conventional kV-switching approach.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.252
Teacher spread0.244 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2023
Admission routes1
Has abstractyes

Explore more

Same topicAdvanced X-ray and CT ImagingFrench-language works237,207