MétaCan
Menu
Back to cohort
Record W4362710259 · doi:10.4209/aaqr.230008

Characterisation of the Aerodynamic Aerosol Classifier Transfer Function for Particle Sizes up to 5 Micrometres

2023· article· en· W4362710259 on OpenAlexaff
Simon Payne, Tyler J. Johnson, Jonathan P. R. Symonds

Bibliographic record

VenueAerosol and Air Quality Research · 2023
Typearticle
Languageen
FieldEngineering
TopicParticle Dynamics in Fluid Flows
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsAerosolAerodynamicsParticle sizeCondensation particle counterMaterials scienceMechanicsParticle numberChemistryMeteorologyPhysicsThermodynamics

Abstract

fetched live from OpenAlex

The Aerodynamic Aerosol Classifier (AAC) classifies particles with the desired aerodynamic diameter by generating opposing centrifugal and drag forces on the particles using rotating concentric cylinders and a clean sheath flow. Particle transmission through the classifier is described by its transfer function, which is an important indicator of classifier performance. Characterisation of the classifier’s transfer function improves the accuracy of its common aerosol applications, such as measuring particle size distributions or providing classified particles to other aerosol instruments for calibration or further analysis. This characterisation is commonly achieved experimentally using a tandem set-up of the same classifier. While this approach was previously used to characterise the AAC’s transfer function for particle aerodynamic diameters up to 2.4 µm using a nebuliser and a Condensation Particle Counter (CPC), the current study expands the AAC’s characterisation up to 5 µm using a condensation aerosol generator and an Optical Particle Counter (OPC). This upper size range is significantly higher than that offered by other common aerosol classifiers, such as the approximate 1 µm upper limit typical of the Differential Mobility Analyser (DMA), and it is well suited to many applications, including OPC calibration, bio-aerosols, drug delivery and inhalation studies, and atmospheric dust analysis. This study found that the AAC maintains its high transmission efficiency (≥ 60%) for particles up to 5 µm and that its transfer function width factor increases (i.e., the distribution becomes narrower) as the aerodynamic diameter increases. Setpoint agreement between two different production AACs remained within 2% over the size range tested. Therefore, the AAC has excellent performance for classifying particles up to 5 µm.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.585
Threshold uncertainty score0.400

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.114
GPT teacher head0.365
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueAerosol and Air Quality ResearchSame topicParticle Dynamics in Fluid FlowsFrench-language works237,207