MétaCan
Menu
Back to cohort
Record W4365128893 · doi:10.1017/wtc.2023.7

A wearable real-time kinetic measurement sensor setup for human locomotion

2023· article· en· W4365128893 on OpenAlexaff
Huawei Wang, Akash Basu, Guillaume Durandau, Massimo Sartori

Bibliographic record

VenueWearable Technologies · 2023
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsMcGill University
FundersH2020 European Research CouncilEuropean Commission
KeywordsMotion captureGround reaction forceForce platformKinematicsInverse dynamicsComputer scienceWearable computerSimulationJoint (building)Pressure sensorCenter of pressure (fluid mechanics)System of measurementAnkleMotion (physics)Artificial intelligenceEngineeringPhysicsMechanical engineeringStructural engineeringMechanicsMedicine

Abstract

fetched live from OpenAlex

Abstract Current laboratory-based setups (optical marker cameras + force plates) for human motion measurement require participants to stay in a constrained capture region which forbids rich movement types. This study established a fully wearable system, based on commercially available sensors (inertial measurement units + pressure insoles), that can measure both kinematic and kinetic motion data simultaneously and support wireless frame-by-frame streaming. In addition, its capability and accuracy were tested against a conventional laboratory-based setup. An experiment was conducted, with 9 participants wearing the wearable measurement system and performing 13 daily motion activities, from slow walking to fast running, together with vertical jump, squat, lunge, and single-leg landing, inside the capture space of the laboratory-based motion capture system. The recorded sensor data were post-processed to obtain joint angles, ground reaction forces (GRFs), and joint torques (via multi-body inverse dynamics). Compared to the laboratory-based system, the established wearable measurement system can measure accurate information of all lower limb joint angles (Pearson’s r = 0.929), vertical GRFs (Pearson’s r = 0.954), and ankle joint torques (Pearson’s r = 0.917). Center of pressure (CoP) in the anterior–posterior direction and knee joint torques were fairly matched (Pearson’s r = 0.683 and 0.612, respectively). Calculated hip joint torques and measured medial–lateral CoP did not match with the laboratory-based system (Pearson’s r = 0.21 and 0.47, respectively). Furthermore, both raw and processed datasets are openly accessible ( https://doi.org/10.5281/zenodo.6457662 ). Documentation, data processing codes, and guidelines to establish the real-time wearable kinetic measurement system are also shared ( https://github.com/HuaweiWang/WearableMeasurementSystem ).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.110
Threshold uncertainty score0.778

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.238
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueWearable TechnologiesSame topicMuscle activation and electromyography studiesFrench-language works237,207