MétaCan
Menu
Back to cohort
Record W4366588674 · doi:10.1186/s40635-023-00506-6

First non-invasive magnetic phrenic nerve and diaphragm stimulation in anaesthetized patients: a proof-of-concept study

2023· article· en· W4366588674 on OpenAlexaff
Alessandro Panelli, Hermann Georges Bartels, Sven Krause, Michael André Verfuß, A. Grimm, Niklas M. Carbon, Julius J. Grunow, Diego Stutzer, Thomas Niederhäuser, Laurent Brochard, Steffen Weber‐Carstens, Stefan J. Schaller

Bibliographic record

VenueIntensive Care Medicine Experimental · 2023
Typearticle
Languageen
FieldMedicine
TopicRespiratory Support and Mechanisms
Canadian institutionsUniversity of Toronto
FundersCharité – Universitätsmedizin Berlin
KeywordsMedicinePhrenic nerveAnesthesiaDiaphragm (acoustics)Diaphragmatic breathingStimulationIntensity (physics)Mechanical ventilationTidal volumeRespiratory systemAnatomyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Mechanical ventilation has side effects such as ventilator-induced diaphragm dysfunction, resulting in prolonged intensive care unit length of stays. Artificially evoked diaphragmatic muscle contraction may potentially maintain diaphragmatic muscle function and thereby ameliorate or counteract ventilator-induced diaphragm dysfunction. We hypothesized that bilateral non-invasive electromagnetic phrenic nerve stimulation (NEPNS) results in adequate diaphragm contractions and consecutively in effective tidal volumes. RESULTS: This single-centre proof-of-concept study was performed in five patients who were 30 [IQR 21-33] years old, 60% (n = 3) females and undergoing elective surgery with general anaesthesia. Following anaesthesia and reversal of muscle relaxation, patients received bilateral NEPNS with different magnetic field intensities (10%, 20%, 30%, 40%); the stimulation was performed bilaterally with dual coils (connected to one standard clinical magnetic stimulator), specifically designed for bilateral non-invasive electromagnetic nerve stimulation. The stimulator with a maximal output of 2400 Volt, 160 Joule, pulse length 160 µs at 100% intensity was limited to 50% intensity, i.e. each single coil had a maximal output of 0.55 Tesla and 1200 Volt. There was a linear relationship between dosage (magnetic field intensity) and effect (tidal volume, primary endpoint, p < 0.001). Mean tidal volume was 0.00, 1.81 ± 0.99, 4.55 ± 2.23 and 7.43 ± 3.06 ml/kg ideal body weight applying 10%, 20%, 30% and 40% stimulation intensity, respectively. Mean time to find an initial adequate stimulation point was 89 (range 15-441) seconds. CONCLUSIONS: Bilateral non-invasive electromagnetic phrenic nerve stimulation generated a tidal volume of 3-6 ml/kg ideal body weight due to diaphragmatic contraction in lung-healthy anaesthetized patients. Further perspectives in critically ill patients should include assessment of clinical outcomes to confirm whether diaphragm contraction through non-invasive electromagnetic phrenic nerve stimulation potentially ameliorates or prevents diaphragm atrophy.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.302
Teacher spread0.281 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueIntensive Care Medicine ExperimentalSame topicRespiratory Support and MechanismsFrench-language works237,207