MétaCan
Menu
Back to cohort
Record W4366590844 · doi:10.7759/cureus.37888

Clinical Outcomes of CAD/CAM (Lithium disilicate and Zirconia) Based and Conventional Full Crowns and Fixed Partial Dentures: A Systematic Review and Meta-Analysis

2023· review· en· W4366590844 on OpenAlexaboutno aff
Gunjan Singh Aswal, Renu Rawat, Dhara Dwivedi, Nitin Prabhakar, Vinod Kumar

Bibliographic record

VenueCureus · 2023
Typereview
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineMeta-analysisDentistryCochrane LibraryLithium disilicateRandomized controlled trialMEDLINEDenturesCohort studyCohortPopulationOrthodonticsSurgeryInternal medicineCeramic

Abstract

fetched live from OpenAlex

Although CAD/CAM (computer-aided design/computer-aided manufacturing) restorations act as a favorable alternative to conventional metal-ceramic restorations for fixed dental prostheses, little is known about their intermediate and persistent clinical performance. This systematic review and meta-analysis aimed to assess the clinical performance in terms of biological, technical, and esthetic aspects and the survival and success ratios for single full crowns (SFCs) and fixed partial dentures (FPDs) fabricated by CAD/CAM and conventional techniques and according to the materials used (zirconia {ZC} and lithium disilicate {LD}). The population, intervention, control, outcome, and study design (PICOS) strategy was used to electronically search key terms in the PubMed, Cochrane Library, Embase, and Wiley Online databases for randomized control trials (RCTs) and cohort studies. The bias risks for RCTs and cohort studies were assessed using the Cochrane collaboration tool and the Newcastle-Ottawa Scale (NOS). Meta-analysis was performed using Rev5 from Cochrane. A total of 13 studies reporting on 1598 restorations in 1161 patients with a mean observation period of 3.6 years (minimum-maximum: 1-9.3 years) met the inclusion criteria. Meta-analysis of the included studies indicated that CAD/CAM manufacturing resulted in 1.17, 1.14, and 16.88 (95% CI: 0.64-2.17, 0.86-1.52, 7.59-37.56) higher biological, technical, and esthetic complications than conventional manufacturing of restorations. However, the difference was significant for esthetic complications only (p<0.00001). A significant difference was observed for all biological, technical, and aesthetic aspects between SFCs and FPDs (odds ratio {OR} = 2.61 vs. 1.78, 95% CI: 1.92-3.56 vs. 1.33-2.38; p<0.00001). The survival ratio of SFCs was 2.69 (95% CI: 1.98-3.65), significantly higher compared to the 1.76 (95% CI: 1.31-2.36) of FPDs (p<0.00001). The success ratio of FPDs at 1.18 (95% CI: 0.83-1.69) was significantly lower compared to SFCs at 2.36 (95% CI: 1.68-3.33). The clinical performance of LD with 2.42 (CI: 1.16-5.03) was significantly higher compared to ZC with 2.22 (CI: 1.78-2.77) (p<0.00001). The biological, technical, and aesthetic behaviors showed similar clinical outcomes between the CAD/CAM and conventional groups. LD could be a good alternative to zirconia, but its intermediate or persistent clinical performance needs to be evaluated. Overall, zirconia and CAD/CAM techniques must evolve further to outclass the conventional techniques used in the fabrication of SFCs and FPDs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.885
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0070.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.190
GPT teacher head0.439
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueCureusSame topicDental materials and restorationsFrench-language works237,207