MétaCan
Menu
Back to cohort
Record W4366603236 · doi:10.1002/mp.16426

Design and characterization of an aperture system and spot configuration for ocular treatments with a gantry‐based spot scanning proton beam

2023· article· en· W4366603236 on OpenAlexaff
Susannah Hickling, Stephen Corner, Jon J. Kruse, A. Deisher

Bibliographic record

VenueMedical Physics · 2023
Typearticle
Languageen
FieldMedicine
TopicOcular Oncology and Treatments
Canadian institutionsCancerCare Manitoba
Fundersnot available
KeywordsAperture (computer memory)OpticsProton therapyIsocenterMaterials scienceIonization chamberMonte Carlo methodBeam (structure)Bragg peakSobpPencil-beam scanningDosimetryCollimated lightProtonNumerical aperturePhysicsNuclear medicineImaging phantomIonizationWavelengthIonLaserNuclear physics

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: Proton therapy is a key modality used in the treatment of ocular melanoma. Traditionally ocular sites are treated using a dedicated eyeline with a passively scattered proton beam and a brass aperture. This work aims to design and characterize a beam-collimating aperture to treat ocular targets with a gantry-based spot scanning proton beam. METHODS: A plastic aperture system that slides into the gantry nozzle of a spot scanning proton beam was designed and constructed. It consists of an intermediate scraper layer to attenuate stray protons and a 3D-printed patient-specific aperture positioned 5.7 cm from the surface of the eye. The aperture system was modeled in TOPAS and Monte Carlo simulations were validated with film measurements. Two different spot configurations were investigated for treatment planning and characterized based on lateral penumbra, central axis (CAX) dose and relative efficiency. Alignment and leakage were investigated through experimental film measurements. Range was verified using a multi-layer ionization chamber. Reference dose measurements were made with a PinPoint 3D ion chamber. Neutron dose was evaluated through Monte Carlo simulations. RESULTS: Aperture alignment with radiation isocenter was determined to be within 0.31 mm at a gantry angle of 0°. A single-spot configuration with a 10 mm diameter aperture yielded film-measured lateral penumbras of 1 mm to 1.25 mm, depending on depth in the spread-out Bragg peak. TOPAS simulations found that a single spot configuration results in a flat dose distribution for a 10 mm diameter aperture and provides a CAX dose of less than 106% for apertures less than 14 mm in diameter. For larger targets, adding four corner spots to fill in the dose distribution is beneficial. Trade-offs between lateral penumbra, CAX dose and relative efficiency were characterized for different spot configurations and can be used for future clinical decision-making. The aperture was experimentally determined to not affect proton beam range, and no concerning leakage radiation or neutron dose was identified. Reference dose measurements with a PinPoint ion chamber were within 2.1% of Monte Carlo calculated doses. CONCLUSION: The aperture system developed in this work provides a method of treating ocular sites on a gantry-based spot scanning proton system. Additional work to develop compatible gaze tracking and gating infrastructure is ongoing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.279
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more