MétaCan
Menu
Back to cohort
Record W4367309142 · doi:10.1117/12.2658198

TouchBand: a modular low-power elastomer-based watchband for touch input and hand gesture recognition

2023· article· en· W4367309142 on OpenAlexaff
Jian Gao, Yiting Wu, Xiulun Yin, Ziqiang Chen, Kieran Morton, John D. W. Madden

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsSmartwatchCapacitive sensingTouchpadCapacitanceTouchscreenProximity sensorModular designWearable computerComputer sciencePrinted circuit boardMobile deviceGestureComputer hardwareGesture recognitionElectrodeElectrical engineeringEngineeringEmbedded systemArtificial intelligence

Abstract

fetched live from OpenAlex

Existing smartwatches offer convenient health monitoring and interfaces with mobile devices. However, the interactivity between a user and a smartwatch suffers from the limited size of the screen and buttons. To improve the usability of smartwatches, novel human-computer interaction methods are introduced into the watchband. To this end, we present a modular lightweight watchband consisting of various capacitive sensing modules—TouchBand. It is made with a flexible printed circuit board (PCB) supporting the bottom electrodes, silver-coated conductive fabric as the top electrodes, and Eco-Flex as the dielectric to electrically separate the PCB and fabric. The watchband incorporates three control modules—(i) two shear-sensitive pressure sensing buttons, (ii) two capacitive sliders, and (iii) one proximity sensing array for hand gesture recognition. Shear forces are captured by analyzing the asymmetric changes in multiple mutual-capacitance readings produced by a shear motion between the top and bottom layers, where overlapped electrodes reside. Sliders pick up changes in proximity as fingers are moved across the sensor surfaces. Hand gestures could be recognized by monitoring the capacitance-based proximity readings between the watchband electrodes and the user’s skin. Eyes-free input to the watch becomes feasible by providing a shear/sliding touch input to the watchband as well as performing a free-hand gesture on the wearing hand. With a flexible printed circuit (FPC) connection to the compact custom electronics, all modules of the watchband were sampled at 50 Hz while consuming 30 mW of power. Meanwhile, the measurement data was wirelessly transmitted through Bluetooth Low-Energy 5.0 (BLE) to a nearby mobile device for real-time data analysis and visualization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0050.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.221
Teacher spread0.205 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2023
Admission routes1
Has abstractyes

Explore more

Same topicAdvanced Sensor and Energy Harvesting MaterialsFrench-language works237,207