MétaCan
Menu
Back to cohort
Record W4367397244 · doi:10.1016/j.jisako.2023.04.006

The use of slice encoding for metal artifact correction (SEMAC) sequencing improves the diagnostic evaluation of graft integrity following anterior cruciate ligament reconstruction

2023· article· en· W4367397244 on OpenAlexaff
Brandon Y. H. Zhao, Nabil A. Khan, Stephanie Wichuk, Mark Sommerfeldt, Anukul Panu, Jacob L. Jaremko, Catherine Hui

Bibliographic record

VenueJournal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine · 2023
Typearticle
Languageen
FieldMedicine
TopicKnee injuries and reconstruction techniques
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsAnterior cruciate ligamentNuclear medicineMedicineMagnetic resonance imagingSagittal planeRadiology

Abstract

fetched live from OpenAlex

OBJECTIVES: To determine whether magnetic resonance imaging (MRI) with metal artifact reduction sequencing is superior to conventional knee MRI in the evaluation of an injured anterior cruciate ligament (ACL) graft, where visualisation on conventional MRI can be limited by the metal artifact from fixation devices. METHODS: Eighteen patients underwent conventional MRI sequence (proton density fat saturated [PDFS]) and two types of metal artifact reduction sequencing MRI (WARP, slice encoding for metal artifact correction (SEMAC); Siemens) following a secondary injury to their ACL reconstructed knee. Six raters with experience in knee MRI evaluation reviewed sagittal PDFS, WARP, and SEMAC sequences, providing semi-quantitative grades for visualisation and diagnostic confidence assessing the ACL, posterior cruciate ligament , menisci, tibial and femoral tunnel margins, and articular cartilage. Intra-class correlation coefficients for inter-rater reliability were evaluated. The 6-rater mean scores for the visualisation and diagnostic confidence derived from each sequence were compared using the Friedman test for multiple paired samples. RESULTS: No statistically significant difference in the ACL visualisation among the sequences was found (p ​= ​0.193). Further, a subgroup analysis was performed in cases evaluated as "moderately blurry" or "indistinct ACL visualisation" on PDFS (58% of cases). SEMAC significantly improved diagnostic confidence in ACL visualisation (p ​= ​0.041) and ACL graft rupture (p ​= ​0.044) compared to PDFS. There was no statistically significant difference in the inter-observer reliability between sequences. The WARP sequence added 2.84 ​± ​0.69 ​min, while SEMAC added 2.95 ​± ​0.40 ​min to the standard knee MRI scan time. CONCLUSION: use of the SEMAC metal reduction sequence significantly improved diagnostic accuracy and confidence in the detection of ACL graft rupture in cases where the ACL was moderately blurry or indistinct on the PDFS sequence. This sequence should be considered as an adjunct to conventional PDFS in cases where graft visualisation is limited by the metal artifact from fixation devices. LEVEL OF EVIDENCE: III.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.010
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.061
GPT teacher head0.326
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueJournal of ISAKOS Joint Disorders & Orthopaedic Sports MedicineSame topicKnee injuries and reconstruction techniquesFrench-language works237,207