MétaCan
Menu
Back to cohort
Record W4367609774 · doi:10.1038/s41551-023-01038-w

Stretchable ultrasonic arrays for the three-dimensional mapping of the modulus of deep tissue

2023· article· en· W4367609774 on OpenAlexaff
Hongjie Hu, Yuxiang Ma, Xiaoxiang Gao, Dawei Song, Mohan Li, Hao Huang, Xuejun Qian, Ray S. Wu, Keren Shi, Hong Ding, Muyang Lin, Xiangjun Chen, Wenbo Zhao, Baiyan Qi, Sai Zhou, Ruimin Chen, Yue Gu, Yimu Chen, Yusheng Lei, Chonghe Wang, Chunfeng Wang, Yitian Tong, Haotian Cui, Abdulhameed Abdal, Yangzhi Zhu, Xinyu Tian, Zhaoxin Chen, Chengchangfeng Lu, Xinyi Yang, Jing Mu, Zhiyuan Lou, Mohammad Eghtedari, Qifa Zhou, Assad A. Oberai, Sheng Xu

Bibliographic record

VenueNature Biomedical Engineering · 2023
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversity of Toronto
FundersAir Force Research LaboratoryUniversity of California, San DiegoNational Institutes of HealthU.S. Department of Health and Human Services
KeywordsBiomedical engineeringElastographyUltrasonic sensorMagnetic resonance imagingUltrasoundEx vivoBiomechanicsImage resolutionMagnetic resonance elastographyMaterials scienceMedicineRadiologyIn vivoComputer scienceAnatomyComputer vision

Abstract

fetched live from OpenAlex

Serial assessment of the biomechanical properties of tissues can be used to aid the early detection and management of pathophysiological conditions, to track the evolution of lesions and to evaluate the progress of rehabilitation. However, current methods are invasive, can be used only for short-term measurements, or have insufficient penetration depth or spatial resolution. Here we describe a stretchable ultrasonic array for performing serial non-invasive elastographic measurements of tissues up to 4 cm beneath the skin at a spatial resolution of 0.5 mm. The array conforms to human skin and acoustically couples with it, allowing for accurate elastographic imaging, which we validated via magnetic resonance elastography. We used the device to map three-dimensional distributions of the Young's modulus of tissues ex vivo, to detect microstructural damage in the muscles of volunteers before the onset of soreness and to monitor the dynamic recovery process of muscle injuries during physiotherapies. The technology may facilitate the diagnosis and treatment of diseases affecting tissue biomechanics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.231
Teacher spread0.225 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations132
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueNature Biomedical EngineeringSame topicUltrasound Imaging and ElastographyFrench-language works237,207