MétaCan
Menu
Back to cohort
Record W4375850237 · doi:10.1186/s42836-023-00177-4

Early clinical and radiological outcomes of the new porous titanium shell in combination with locking screw in revision total hip arthroplasty

2023· article· en· W4375850237 on OpenAlexaboutno aff
Shahril R. Shaarani, Monketh Jaibaji, Khaled M. Yaghmour, Georges Vles, Fares S. Haddad, Sujith Konan

Bibliographic record

VenueArthroplasty · 2023
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineWOMACOsteoarthritisRadiological weaponRadiographyHarris Hip ScoreSurgeryTotal hip arthroplasty

Abstract

fetched live from OpenAlex

INTRODUCTION: Extensive acetabular bone loss and poor bone quality are two key challenges often encountered in revision total hip arthroplasty. A new 3D-printed porous acetabular shell has been made available with the option to insert multiple variable-angle locking screws. We sought to evaluate the early clinical and radiological outcomes of this construct. METHODS: A retrospective review of patients operated by two surgeons was performed in a single institution. Fifty-nine revision hip arthroplasties were performed in 55 patients (34 female; mean age 68.8 ± 12.3 years) for Paprosky defects I (n = 21), IIA/B (n = 22), IIC (n = 9), III (n = 7) between February 2018 and January 2022 using the novel porous titanium acetabular shell and multiple variable angle locking screws. Postoperative clinical and radiographic outcomes were locally maintained. Patient-reported outcome measures collected included the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Oxford Hip Score, and the 12-item Short Form Survey. RESULTS: After a mean follow-up of 25.7 ± 13.9 months, two cases of shell migration were noted. One patient had a failed constrained mechanism and received revision to a cemented dual mobility liner. No other acetabular shells showed any evidence of radiographic loosening at the final follow-up. Preoperatively, 21 defects were classified as Paprosky grade I, 19 grade IIA, 3 grade IIB, 9 IIC, 4 grade IIIA, and 3 IIIB. The mean postoperative WOMAC function score was 84 (SD 17), WOMAC (stiffness) 83 (SD 15), WOMAC (pain) 85 (SD 15), and WOMAC (global) 85 (SD 17). The mean postoperative OHS was 83 (SD 15), and mean SF-12 physical score was 44 (SD 11). CONCLUSION: The additional augmentation of porous metal acetabular shells with multiple variable-angle locking screws provides reliable initial fixation with good clinical and radiological outcomes in the short term. Further studies are needed to establish the medium- and long-term outcomes. LEVEL OF EVIDENCE: IV.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.050
Threshold uncertainty score0.568

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.291
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueArthroplastySame topicOrthopaedic implants and arthroplastyFrench-language works237,207