MétaCan
Menu
Back to cohort
Record W4376272090 · doi:10.1212/cpj.0000000000200160

Diagnostic Accuracy of Ambulatory EEG vs Routine EEG in Patients With First Single Unprovoked Seizure

2023· article· en· W4376272090 on OpenAlexaff
Lizbeth Hernández‐Ronquillo, Lilian Thorpe, Cindy Feng, Gary Hunter, Dianne Dash, Tabrez Hussein, Chelsea Dolinsky, Karen Waterhouse, Pragma Laboni Roy, Nathalie Jetté

Bibliographic record

VenueNeurology Clinical Practice · 2023
Typearticle
Languageen
FieldMedicine
TopicEpilepsy research and treatment
Canadian institutionsBC Children's HospitalRoyal University HospitalLakeridge HealthSaskatchewan Health Authority
FundersNational Institute of Neurological Disorders and StrokeNational Institutes of Health
KeywordsElectroencephalographyIctalAmbulatoryMedicineEpilepsyAudiologySurgeryPsychiatry

Abstract

fetched live from OpenAlex

Background and Objective: To evaluate the diagnostic accuracy of the ambulatory EEG (aEEG) at detecting interictal epileptiform discharges (IEDs)/seizures compared with routine EEG (rEEG) and repetitive/second rEEG in patients with a first single unprovoked seizure (FSUS). We also evaluated the association between IED/seizures on aEEG and seizure recurrence within 1 year of follow-up. Methods: We prospectively evaluated 100 consecutive patients with FSUS at the provincial Single Seizure Clinic. They underwent 3 sequential EEG modalities: first rEEG, second rEEG, and aEEG. Clinical epilepsy diagnosis was ascertained based on the 2014 International League Against Epilepsy definition by a neurologist/epileptologist at the clinic. An EEG-certified epileptologist/neurologist interpreted all 3 EEGs. All patients were followed up for 52 weeks until they had either second unprovoked seizure or maintained single seizure status. Accuracy measures (sensitivity, specificity, negative and positive predictive values, and likelihood ratios), receiver operating characteristic (ROC) analysis, and area under the curve (AUC) were used to evaluate the diagnostic accuracy of each EEG modality. Life tables and the Cox proportional hazard model were used to estimate the probability and association of seizure recurrence. Results: Ambulatory EEG captured IED/seizures with a sensitivity of 72%, compared with 11% for the first rEEG and 22% for the second rEEG. The diagnostic performance of the aEEG was statistically better (AUC: 0.85) compared with the first rEEG (AUC: 0.56) and second rEEG (AUC: 0.60). There were no statistically significant differences between the 3 EEG modalities regarding specificity and positive predictive value. Finally, IED/seizure on the aEEG was associated with more than 3 times the hazard of seizure recurrence. Discussion: The overall diagnostic accuracy of aEEG at capturing IED/seizures in people presenting with FSUS was higher than the first and second rEEGs. We also found that IED/seizures on the aEEG were associated with an increased risk of seizure recurrence. Classification of Evidence: This study provides Class I evidence supporting that, in adults with First Single Unprovoked Seizure (FSUS), 24-h ambulatory EEG has increased sensitivity when compared with routine and repeated EEG.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.087
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.086
Threshold uncertainty score0.921

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.087
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.376
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueNeurology Clinical PracticeSame topicEpilepsy research and treatmentFrench-language works237,207