MétaCan
Menu
Back to cohort
Record W4376457149 · doi:10.1109/tdei.2023.3274731

Prebreakdown and Breakdown Behavior of Low Pour Point Dielectric Liquids Under Negative Lightning Impulse Voltage

2023· article· en· W4376457149 on OpenAlexafffund
T. Jayasree, Paweł Rózga, I. Fofana, U. Mohan Rao, S. Brettschneider, Patrick Picher, Esperanza Mariela Rodriguez-Celis

Bibliographic record

VenueIEEE Transactions on Dielectrics and Electrical Insulation · 2023
Typearticle
Languageen
FieldEngineering
TopicPower Transformer Diagnostics and Insulation
Canadian institutionsHydro-QuébecUniversité du Québec à Chicoutimi
FundersNatural Sciences and Engineering Research Council of CanadaNarodowa Agencja Wymiany AkademickiejHydro-Québec
KeywordsImpulse (physics)Materials scienceElectric breakdownDielectricVoltageBreakdown voltageLightning (connector)Dielectric strengthElectrical engineeringMechanicsPhysicsOptoelectronicsEngineeringThermodynamicsPower (physics)Classical mechanics

Abstract

fetched live from OpenAlex

In this article, some investigations on the prebreakdown and breakdown phenomena of low pour point insulating liquids under negative lightning impulse (LI) voltage are reported. The tested liquids include mineral oil (MO), a typical synthetic ester (TSE), and two low-pour point synthetic esters. These liquids underwent accelerated thermal aging. The nonaged and aged samples were subjected to LIs using a point-plane electrode arrangement. The discussions are focused on the initiation of partial discharges, propagation of streamers, and breakdown behavior in the nonaged and aged liquids. The investigated parameters include inception voltage, LI breakdown voltage, streamer acceleration voltage, and streamer velocity. The results are supported by the oscillographs of the light activity that is recorded during the discharge process. The prebreakdown phenomenon noticed in the TSE vis-à-vis mineral insulating oil is in line with the existing literature. Importantly, it is noticed that the inception and breakdown voltages of the nonaged low pour point synthetic esters are similar to nonaged MO. In addition, the inception and breakdown voltages of the aged low pour point synthetic esters are noticed to be higher than that of the aged MO. These results add to the arguments in favor of replacing MOs in power transformers.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.227
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2023
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Dielectrics and Electrical InsulationSame topicPower Transformer Diagnostics and InsulationFrench-language works237,207