Frequency unlocking-based MEMS bifurcation sensors
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
MEMS resonators exhibit rich dynamic behaviors under the internal resonance regime. In this work, we present a novel MEMS bifurcation sensor that exploits frequency unlocking due to a 1:3 internal resonance between two electrostatically coupled micro-resonators. The proposed detection mechanism allows the sensor to operate in binary (digital) and analog modes, depending on whether the sensor merely detects a significant jump event in the peak frequency upon unlocking or measures the shift in the peak frequency after unlocking and uses it in conjunction with a calibration curve to estimate the corresponding change in stimulus. We validate the success of this sensor paradigm by experimentally demonstrating charge detection. High charge resolutions are achieved in binary mode, up to 0.137 fC, and in analog mode, up to 0.01 fC. The proposed binary sensor enables extraordinarily high detection resolutions due to the excellent frequency stability under internal resonance and the high signal-to-noise ratio of the shift in peak frequency. Our findings offer new opportunities for high-performance ultrasensitive sensors.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it