MétaCan
Menu
Back to cohort
Record W4377115948 · doi:10.3390/bios13050558

Plasmonic Biosensor on the End-Facet of a Dual-Core Single-Mode Optical Fiber

2023· article· en· W4377115948 on OpenAlexaff
Fatemeh Fouladi Mahani, Arash Mokhtari, Pierre Berini

Bibliographic record

VenueBiosensors · 2023
Typearticle
Languageen
FieldEngineering
TopicPlasmonic and Surface Plasmon Research
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsBiosensorMaterials scienceOptical fiberPlasmonOptoelectronicsFacet (psychology)OpticsSingle-mode optical fiberWaveguideCore (optical fiber)Fiber optic sensorSurface plasmonNanotechnologyPhysics

Abstract

fetched live from OpenAlex

Optical biosensors target widespread applications, such as drug discovery, medical diagnostics, food quality control, and environmental monitoring. Here, we propose a novel plasmonic biosensor on the end-facet of a dual-core single-mode optical fiber. The concept uses slanted metal gratings on each core, interconnected by a metal stripe biosensing waveguide to couple the cores via the propagation of surface plasmons along the end facet. The scheme enables operation in transmission (core-to-core), thereby eliminating the need to separate the reflected light from the incident light. Importantly, this simplifies and reduces the cost of the interrogation setup because a broadband polarization-maintaining optical fiber coupler or circulator is not required. The proposed biosensor enables remote sensing because the interrogation optoelectronics can be located remotely. In vivo biosensing and brain studies are also enabled because the end-facet can be inserted into a living body, once properly packaged. It can also be dipped into a vial, precluding the need for microfluidic channels or pumps. Bulk sensitivities of 880 nm/RIU and surface sensitivities of 1 nm/nm are predicted under spectral interrogation using cross-correlation analysis. The configuration is embodied by robust and experimentally realizable designs that can be fabricated, e.g., using metal evaporation and focused ion beam milling.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.070
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.272
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2023
Admission routes1
Has abstractyes

Explore more

Same venueBiosensorsSame topicPlasmonic and Surface Plasmon ResearchFrench-language works237,207